CT引导下椎间盘炎-骨髓炎活检:穿刺针规格与微生物学结果

CT-guided discitis-osteomyelitis biopsies: needle gauge and microbiology results.
PubMed 文献 · Skeletal Radiol · 2020-04-18

该研究回顾了2002至2019年在本机构因疑似椎间盘炎-骨髓炎行CT引导下活检的241例病例,比较不同穿刺针规格的微生物学结果。整体活检阳性率39%、敏感度56%、特异度89%、准确率66%;11-13G针与14-20G针的合并阳性率分别为56%和36%,比值比2.29(P=0.021)。结论提示使用内径更大/规格更低的穿刺针可能提高培养出致病微生物的可能性。

要点

  • 疑似椎间盘炎-骨髓炎行CT引导活检时,选用较大内径(较低G数)穿刺针可能提高微生物培养阳性率。
  • 11-13G针合并阳性率56%,14-20G针36%,两组比值比2.29(P=0.021)。
  • 整体活检阳性率39%、敏感度56%、特异度89%、准确率66%。

核心结论

  • 使用内径更大/规格更低(较低G数)的活检针可能提高CT引导下椎间盘炎-骨髓炎活检培养出致病微生物的可能性。

研究设计与样本

  • 回顾性研究,纳入2002至2019年在本机构因疑似椎间盘炎-骨髓炎行CT引导下活检的全部病例,共241例(年龄59±18岁;女性88例[35%],男性162例[65%])。
  • 通过病历回顾获取活检部位、穿刺针类型与规格、微生物学、病理学及临床和影像随访资料,计算阳性率、敏感度、特异度、准确率,并进行不同针规格的配对分析及比值比计算。
  • 真实疾病状态(是否存在感染)通过病理结果(205例,86%)或临床和影像随访(36例,14%)确定。

关键影像表现/征象

  • 最常见的真阳性病原体为金黄色葡萄球菌(31例,33%)。

诊断标准与关键数值

  • 整体活检阳性率39%、敏感度56%、特异度89%、准确率66%。
  • 11-13G针合并活检阳性率56%、敏感度69%、特异度71%、准确率69%;14-20G针合并阳性率36%、敏感度53%、特异度91%、准确率65%;两组比值比2.29(P=0.021)。
  • 11-14G针合并活检阳性率48%、敏感度63%、特异度85%、准确率68%;16-20G针合并阳性率32%、敏感度49%、特异度91%、准确率64%;两组比值比2.02(P=0.0086)。

临床应用与阅片要点

  • 作者认为,对于CT引导下椎间盘炎-骨髓炎活检,使用内径更大/规格更低(较低G数)的穿刺针可能提高培养出致病微生物的可能性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the microbiology results and needle gauge for CT-guided biopsies of suspected discitis-osteomyelitis.

METHODS: All CT-guided biopsies performed for suspected discitis-osteomyelitis at our institution between 2002 and 2019 were reviewed. Biopsy location, needle type and gauge, microbiology, pathology, and clinical and imaging follow-up were obtained through chart review. Yield, sensitivity, specificity, and accuracy were calculated. A pairwise analysis of different needle gauges was also performed with calculations of odds ratios. Naïve Bayes predictive modeling was performed.

RESULTS: 241 (age: 59 ± 18 years; 88 [35%] F, 162 [65%] M) biopsies were performed. There were 3 (1%) 11 gauge (G), and 13 (5%) 12-G biopsies; 23 (10%) 13-G biopsies; 75 (31%) 14-G biopsies; and 90 (37%) 16-G, 33 (14%) 18-G, and 4 (2%) 20 G biopsies. True disease status (presence of infection) was determined via either pathology findings (205, 86%) or clinical and imaging follow-up (36, 14%). The most common true positive pathogen was Staphylococcus aureus (31, 33%). Overall biopsy yield, sensitivity, specificity, and accuracy were 39%, 56%, 89%, and 66%, respectively. Pooled biopsy yield, sensitivity, specificity, and accuracy was 56%, 69%, 71%, and 69% for 11-13-G needles and 36%, 53%, 91%, and 65% for 14-20-G needles, respectively, with an odds ratio between the two groups of 2.29 (P = 0.021). Pooled biopsy yield, sensitivity, specificity, and accuracy was 48%, 63%, 85%, and 68% for 11-14-G needles and 32%, 49%, 91%, and 64% for 16-20-G needles, respectively, with an odds ratio between the two groups of 2.02 (P = 0.0086).

CONCLUSION: The use of a larger inner bore diameter/lower gauge biopsy needle may increase the likelihood of culturing the causative microorganism for CT-guided biopsies of discitis-osteomyelitis.

来源:Skeletal Radiol,查看原文。版权归原作者所有。