文献速递骨肌DR

基于深度学习和膝关节X线片的髌骨高度自动测量系统的开发

Development of automatic measurement for patellar height based on deep learning and knee radiographs.
PubMed 文献 · Eur Radiol · 2020-04-23

本研究利用1018张左膝X线片开发基于深度学习的髌骨高度参数(ISI、CDI、MCDI、KI)自动测量算法,并在200张左膝和200张右膝X线片上测试。算法对ISI、CDI、KI的预测与人工测量参考标准相比具有高准确性(左膝ICC=0.91-0.95,右膝ICC=0.87-0.96),但对MCDI准确性较低(左膝ICC=0.65,右膝ICC=0.62)。算法性能达到或超过放射科医生对ISI、CDI、KI的人工测量。

要点

  • 深度学习系统可自动测量膝关节X线片上的ISI、CDI和KI,准确性高。
  • 该系统对MCDI的测量准确性较低(左膝ICC=0.65,右膝ICC=0.62)。
  • 系统对ISI、CDI、KI的测量性能达到或超过放射科医生的人工测量。

诊断标准与关键数值

  • ISI、CDI、KI预测性能:左膝ICC=0.91-0.95,r=0.84-0.91,MAD=0.02-0.05,RMS=0.02-0.07;右膝ICC=0.87-0.96,r=0.78-0.92,MAD=0.02-0.06,RMS=0.02-0.10。
  • MCDI预测性能:左膝ICC=0.65,r=0.50,MAD=0.14,RMS=0.18;右膝ICC=0.62,r=0.47,MAD=0.15,RMS=0.20。
  • 以人工测量为参考标准,采用ICC、Pearson相关系数、MAD、RMS和Bland-Altman图评估系统预测性能。

局限性

  • 作者指出当前系统对MCDI的预测准确性较低(左膝ICC=0.65,右膝ICC=0.62)。
  • 作者认为用更多数据进一步训练系统将提高其在临床实践中的效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop and evaluate the performance of a deep learning-based system for automatic patellar height measurements using knee radiographs.

METHODS: The deep learning-based algorithm was developed with a data set consisting of 1018 left knee radiographs for the prediction of patellar height parameters, specifically the Insall-Salvati index (ISI), Caton-Deschamps index (CDI), modified Caton-Deschamps index (MCDI), and Keerati index (KI). The performance and generalizability of the algorithm were tested with 200 left knee and 200 right knee radiographs, respectively. The intra-class correlation coefficient (ICC), Pearson correlation coefficient, mean absolute difference (MAD), root mean square (RMS), and Bland-Altman plots for predictions by the system were evaluated in comparison with manual measurements as the reference standard.

RESULTS: Compared with the reference standard, the deep learning-based algorithm showed high accuracy in predicting the ISI, CDI, and KI (left knee ICC = 0.91-0.95, r = 0.84-0.91, MAD = 0.02-0.05, RMS = 0.02-0.07; right knee ICC = 0.87-0.96, r = 0.78-0.92, MAD = 0.02-0.06, RMS = 0.02-0.10), but not the MCDI (left knee ICC = 0.65, r = 0.50, MAD = 0.14, RMS = 0.18; right knee ICC = 0.62, r = 0.47, MAD = 0.15, RMS = 0.20). The performance of the algorithm met or exceeded that of manual determination of ISI, CDI, and KI by radiologists.

CONCLUSIONS: In its current state, the developed system can predict the ISI, CDI, and KI for both left and right knee radiographs as accurately as radiologists. Training the system further with more data would increase its utility in helping radiologists measure patellar height in clinical practice.

KEY POINTS: • Objective and reliable measurement of patellar height parameters is important for clinical diagnosis and the development of a treatment strategy. • Deep learning can be used to create an automatic patellar height measurement system based on knee radiographs. • The deep learning-based patellar height measurement system achieves comparable performance to radiologists in measuring ISI, CDI, and KI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ye Q, Shen Q, Yang W, et al. Development of automatic measurement for patellar height based on deep learning and knee radiographs. Eur Radiol. 2020. PMID: 32328760. doi:10.1007/s00330-020-06856-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。