超声表现有助于决定部分关节面肩胛下肌腱撕脱的修复
本研究纳入52例厚度超过50%的PASTA病例和52例年龄性别匹配的肩胛下肌腱完整病例,由两名盲法骨科医生解读超声视频,评估六种表现。超声诊断PASTA的敏感度为64.7%、特异度为94.1%、准确率为79.4%;回声改变敏感度最高,变薄和分层特异度达100%;软骨界面征敏感度在长轴和短轴图像中均较低。
要点
- 超声诊断PASTA特异度高(94.1%),准确率中等(79.4%),敏感度仅64.7%。
- 变薄和分层特异度最高达100%,回声改变在短轴敏感度最高。
- 软骨界面征敏感度低:长轴17.6%,短轴29.4%,与既往报道不同。
关键影像表现/征象
- 评估的六种超声表现包括回声缺损、肌腱分层、回声改变、肌腱厚度、肌腱纤维模式和软骨界面征。
- 短轴回声改变敏感度最高,变薄和分层特异度最高达100%。
- 软骨界面征敏感度在长轴图像为17.6%,短轴图像为29.4%。
诊断标准与关键数值
- 超声诊断PASTA的敏感度64.7%、特异度94.1%、准确率79.4%。
- 变薄和分层特异度均为100%。
- 软骨界面征敏感度:长轴图像17.6%,短轴图像29.4%。
临床应用与阅片要点
- 超声诊断PASTA特异度高,可用于辅助修复决策。
- 短轴回声改变敏感度最高,变薄和分层特异度高。
- 软骨界面征敏感度低,与既往报道不同。
- 诊断敏感度受检查者超声经验影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Ultrasound (US) is useful for diagnosing full-thickness rotator cuff tears and high-grade partial-thickness bursal-side tears. However, anisotropy artifacts make it difficult to identify partial articular supraspinatus tendon avulsion (PASTA) by US. This study was performed to determine the diagnostic accuracy of US for PASTA and to uncover sensitive findings that could aid decisions to repair.
METHODS: Patients who underwent preoperative US examinations and supraspinatus tendon confirmation by arthroscopic examinations were enrolled. We analyzed 52 PASTA cases involving greater than 50% thickness of the tendon and 52 age- and sex-matched cases with an intact supraspinatus. Two orthopedic surgeons blinded to the diagnosis interpreted US videos of the supraspinatus tendon. Six findings (echo defect, tendon delamination, echo change, tendon thickness, tendon fiber pattern, and cartilage interface sign) were assessed. We calculated the sensitivity, specificity, and accuracy for each US finding.
RESULTS: The cases consisted of 46 men and 58 women. The US diagnosis of PASTA showed sensitivity of 64.7%, specificity of 94.1%, and accuracy of 79.4%. The echo change in the short axis showed the highest sensitivity. Thinning and delamination showed the highest specificity of 100%. In contrast to previous reports, the sensitivity of the cartilage interface sign was low in both long-axis images (17.6%) and short-axis images (29.4%).
CONCLUSIONS: Preoperative diagnostic US to aid decisions regarding PASTA repair showed high specificity (94.1%) and moderate accuracy (79.4%). However, the sensitivity was only 64.7% and was affected by the examiner's experience with US.
引用
- Yoon K, Kim H, Han SB, et al. Ultrasound Findings Aid Decisions to Repair Partial Articular Supraspinatus Tendon Avulsion. J Ultrasound Med. 2020. PMID: 32324303. doi:10.1002/jum.15307
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。