文献速递甲状腺与浅表US

对比增强超声定性分析诊断≤1 cm、TR3-5良性及恶性甲状腺结节的价值

Qualitative analysis of contrast-enhanced ultrasound in the diagnosis of small, TR3-5 benign and malignant thyroid nodules measuring ≤1 cm.
PubMed 文献 · Br J Radiol · 2020-04-09

回顾性纳入2016年1月至2018年3月上海某院154例患者共185个≤1 cm实性甲状腺结节,评估对比增强超声(CEUS)定性分析与2017版TI-RADS对良恶性的诊断效能。CEUS定性分析总分诊断恶性结节的AUC为0.916,高于TI-RADS TR5分类的AUC 0.738,特异度89.29%高于55.95%。

要点

  • CEUS定性分析诊断≤1 cm实性甲状腺恶性结节的AUC为0.916,高于TI-RADS TR5分类的0.738。
  • CEUS定性分析特异度89.29%,高于TI-RADS TR5分类的55.95%。
  • 良恶性结节在增强程度、增强模式、边界、形态及增强均匀性上差异有统计学意义(p<0.05)。

关键影像表现/征象

  • 良恶性结节在增强程度、增强模式、边界、形态及增强均匀性上差异有统计学意义(p<0.05)。
  • 良恶性结节在增强完整性和增强病灶大小上差异无统计学意义(p>0.05)。

诊断标准与关键数值

  • TI-RADS分类TR5诊断恶性结节的敏感度90.10%、特异度55.95%、准确率74.59%、阳性预测值72.22%、阴性预测值82.46%(AUC=0.738;95%CI 0.663-0.813)。
  • CEUS定性分析指标总分诊断恶性结节的敏感度86.13%、特异度89.29%、准确率87.57%、阳性预测值90.63%、阴性预测值84.27%(AUC=0.916;95%CI 0.871-0.961)。

临床应用与阅片要点

  • 对≤1 cm实性甲状腺结节,可依据CEUS定性分析指标总分评估恶性风险,其特异度高于TI-RADS TR5分类。
  • 阅片时关注增强程度、增强模式、边界、形态及增强均匀性,这些特征在良恶性结节间差异有统计学意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance of contrast-enhanced ultrasound in the diagnosis of small, solid, TR3-5 benign and malignant thyroid nodules (≤1 cm).

METHODS: From January 2016 to March 2018, 185 thyroid nodules from 154 patients who underwent contrast enhanced ultrasound (CEUS) and fine-needle aspiration or thyroidectomy in Shanghai General Hospital were included. The χ2 test was used to compare the CEUS characteristics of benign and malignant thyroid nodules, and the CEUS features of malignant nodules assigned scores. The total score of the CEUS features and the scores of the above nodules were evaluated according to the latest 2017 version of the Thyroid Imaging Reporting and Data System (TI-RADS). The diagnostic performance of the two were compared based on the receiver operating characteristic curves generated for benign and malignant thyroid nodules.

RESULTS: The degree, enhancement patterns, boundary, shape, and homogeneity of enhancement in thyroid small solid nodules were significantly different (p<0.05). No significant differences were seen between benign and malignant thyroid nodules regarding completeness of enhancement and size of enhanced lesions (p>0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the TI-RADS classification TR5 in diagnosis of malignant nodules were 90.10%, 55.95%, 74.59%, 72.22%, and 82.46%, respectively (area under the curve [AUC]=0.738; 95% confidence interval[CI], 0.663-0.813). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the total score of CEUS qualitative analysis indicators were 86.13%, 89.29%, 87.57%, 90.63%, and 84.27% respectively (AUC = 0.916; 95% CI, 0.871-0.961).

CONCLUSION: CEUS qualitative analysis is superior to TI-RADS in evaluating the diagnostic performance of small, solid thyroid nodules. Qualitative analysis of CEUS has a significantly higher specificity for diagnosis of malignant thyroid nodules than TI-RADS.

ADVANCES IN KNOWLEDGE: The 2017 version of TI-RADS has recently suggested the malignant stratification of thyroid nodules by ultrasound. In this paper we applied this system and CEUS to evaluate 185 nodules and compare the results with pathological findings to access the diagnostic performance.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Li X, Gao F, Li F, et al. Qualitative analysis of contrast-enhanced ultrasound in the diagnosis of small, TR3-5 benign and malignant thyroid nodules measuring ≤1 cm. Br J Radiol. 2020. PMID: 32242748. doi:10.1259/bjr.20190923

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。