文献速递头颈甲状腺与浅表MR

扩散加权MR成像能否作为预测甲状腺乳头状癌甲状腺外侵犯的工具?

Can Diffusion-Weighted MR Imaging Be Used as a Tool to Predict Extrathyroidal Extension in Papillary Thyroid Carcinoma?
PubMed 文献 · Acad Radiol · 2020-04-14

本研究纳入238例经病理确诊的甲状腺乳头状癌患者,术前接受多b值扩散加权MR成像(b=300、500、800 s/mm²),比较有无甲状腺外侵犯及微小与广泛侵犯组间的ADC值。结果显示ADC500的AUC为0.905,高于ADC300和ADC800,鉴别有无甲状腺外侵犯的截断值为1.407×10⁻³ mm²/s,敏感度80.7%、特异度86.7%。结论认为ADC值可作为评估甲状腺外侵犯的有效工具,b=500 s/mm²时表现最佳。

要点

  • 甲状腺乳头状癌伴甲状腺外侵犯者ADC300、ADC500、ADC800均显著低于无侵犯者。
  • ADC500鉴别有无甲状腺外侵犯的AUC为0.905,优于ADC300(0.607)和ADC800(0.770)。
  • ADC500截断值1.407×10⁻³ mm²/s,敏感度80.7%、特异度86.7%。

核心结论

  • ADC值可作为评估甲状腺乳头状癌甲状腺外侵犯这一侵袭性组织学特征的有效工具。
  • b=500 s/mm²时的ADC值对甲状腺外侵犯的无创术前评估表现最佳。

研究设计与样本

  • 研究纳入238例经病理确诊的甲状腺乳头状癌患者,于2015年1月至2017年12月间接受术前多b值扩散加权MR成像(b=300、500、800 s/mm²)。
  • 按甲状腺外侵犯程度将患者分为无侵犯、微小侵犯和广泛侵犯三组,比较各组ADC值。
  • 采用受试者工作特征分析比较ADC值预测甲状腺外侵犯的诊断效能,并用Delong检验比较曲线下面积差异。

关键影像表现/征象

  • 伴甲状腺外侵犯的甲状腺乳头状癌ADC300、ADC500、ADC800值均显著低于无侵犯者(分别为p=0.001、p<0.001、p<0.001)。

诊断标准与关键数值

  • ADC500鉴别有无甲状腺外侵犯的曲线下面积为0.905,高于ADC300的0.607和ADC800的0.770(p<0.001)。
  • ADC500鉴别有无甲状腺外侵犯的截断值为1.407×10⁻³ mm²/s,敏感度80.7%,特异度86.7%,曲线下面积0.905。

临床应用与阅片要点

  • 术前多b值扩散加权MR成像测量的ADC值可用于无创评估甲状腺乳头状癌是否伴甲状腺外侵犯。
  • b=500 s/mm²时ADC值对甲状腺外侵犯的鉴别效能最佳,ADC500截断值1.407×10⁻³ mm²/s可供参考。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate whether quantitative diffusion-weighted MR imaging (DWI) with multi-b values can be used as a tool to predict the aggressiveness by using the histological feature of extrathyroidal extension (ETE) in papillary thyroid carcinoma (PTC).

MATERIALS AND METHODS: 238 patients were pathologically confirmed as PTCs underwent preoperative multi-b value DWI (300, 500, and 800 s/mm2) between January 2015 and December 2017. The patients were divided into three groups according to the degree of ETE: without ETE, minimal ETE, and extensive ETE. The apparent diffusion coefficients (ADCs) were evaluated for three different b values (b = 300 s/mm2, b = 500 s/mm2, and b = 800 s/mm2). The ADC values of the groups with and without ETE, minimal and extensive ETE were compared. The diagnostic relevance of the ADC values in terms of predicting ETE was compared using a receiver operating characteristic analysis. Differences between the areas under the curves (AUCs) were compared by using a Delong test.

RESULTS: PTCs with ETE had significantly lower ADC300, ADC500 and ADC800 values than PTCs without ETE (p = 0.001, p < 0.001, and p < 0.001, respectively). The AUC of the mean ADC500 value (0.905) was higher than that of the ADC300 and ADC800 values (0.607 and 0.770, respectively) in differentiating ETE from without ETE (p < 0.001). The cut-off value of ADC500 to discriminate PTCs with and without ETE was determined at 1.407 × 10-3 mm2/s, with sensitivity of 80.7%, specificity of 86.7%, and an AUC of 0.905.

CONCLUSION: The ADC value can be demonstrated an effective tool for evaluating the aggressiveness with the histological feature of ETE in PTC. In particular, ADC value at b = 500 s/mm2 showed the best performance for noninvasive preoperative evaluation of ETE.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Hu S, Zhang H, Wang X, et al. Can Diffusion-Weighted MR Imaging Be Used as a Tool to Predict Extrathyroidal Extension in Papillary Thyroid Carcinoma? Acad Radiol. 2020. PMID: 32303443. doi:10.1016/j.acra.2020.03.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。