文献速递头颈甲状腺与浅表CT

多期多排CT鉴别复发性甲状腺癌与残留非恶性甲状腺组织

Distinguishing Recurrent Thyroid Cancer from Residual Nonmalignant Thyroid Tissue Using Multiphasic Multidetector CT.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-04-23

回顾性研究对比29例复发性甲状腺癌、29例正常甲状腺和29例病变甲状腺(甲状腺炎/多结节甲状腺)在多期多排CT平扫、动脉期(25秒)、静脉期(55秒)和延迟期(85秒)的CT值,发现复发性癌CT值最低、病变甲状腺居中、正常甲状腺最高,各期差异均有统计学意义(P < .001)。平扫期鉴别良恶性的AUC最高为0.983(95% CI,0.954-1),阈值≤62时敏感度/特异度分别为0.966/0.983。

要点

  • 复发性甲状腺癌的CT值在各期均低于残留病变甲状腺和正常甲状腺组织(P < .001)。
  • 平扫期鉴别复发性癌与良性甲状腺组织的AUC为0.983,阈值≤62时敏感度0.966、特异度0.983。
  • 鉴别信息量平扫期最大,其次为动脉期,临床方案应包含平扫期。

核心结论

  • 多期多排CT可高准确率地鉴别复发性甲状腺癌与残留非恶性甲状腺组织。
  • 鉴别信息量最大的是平扫图像,其次为动脉期。
  • 最佳临床方案可包含任意期相,但应包含平扫期。

研究设计与样本

  • 回顾性研究,比较29个复发性甲状腺癌病灶、29个正常甲状腺和29个病变甲状腺(甲状腺炎/多结节甲状腺)的CT值。
  • 采用多期多排CT平扫、动脉期(25秒)、静脉期(55秒)和延迟期(85秒)扫描。
  • 采用方差分析比较各期不同组织类型的CT值,采用逻辑回归和受试者工作特征分析评估CT值预测复发的性能。

关键影像表现/征象

  • 三种组织均呈近乎平行的强化特征,表现为流入-流出模式。
  • 复发性甲状腺癌CT值最低,病变甲状腺居中,正常甲状腺最高,四个期相各组间差异均有统计学意义(P < .001)。

诊断标准与关键数值

  • 平扫期鉴别复发性癌与病变/正常甲状腺组织的AUC为0.983(95% CI,0.954-1),阈值≤62,敏感度/特异度分别为0.966/0.983。
  • 动脉期鉴别性能次于平扫期。

临床应用与阅片要点

  • 阅片时注意平扫期CT值≤62提示复发性甲状腺癌可能,需结合动脉期等期相综合判断。
  • 临床协议可包含任意期相,但应包含平扫期以获取最大鉴别信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: During thyroidectomy incomplete resection of the thyroid gland may occur. This complicates the imaging surveillance of these patients as residual thyroid needs to be distinguished from local recurrence. Therefore, the purpose of this study was to determine if multiphasic multi-detector computed tomography (4D-MDCT) can differentiate residual nonmalignant thyroid tissue and recurrent thyroid carcinoma after thyroidectomy.

MATERIALS AND METHODS: In this retrospective study, Hounsfield unit values on multiphasic multidetector CT in precontrast, arterial (25 seconds), venous (55 seconds), and delayed (85 seconds) phases were compared in 29 lesions of recurrent thyroid cancer, 29 with normal thyroid, and 29 with diseased thyroid (thyroiditis/multinodular thyroid). The comparison of Hounsfield unit values among lesion types by phase was performed using ANOVA. The performance of Hounsfield unit values to predict recurrence was evaluated by logistic regression and receiver operating characteristic analysis.

RESULTS: All 3 tissue types had near-parallel enhancement characteristics, with a wash-in-washout pattern. Statistically different Hounsfield unit density was noted between the recurrence (lowest Hounsfield unit), diseased (intermediate Hounsfield unit), and normal (highest Hounsfield unit) thyroid groups throughout all 4 phases (P < .001 for each group and in each phase). Dichotomized recurrence-versus-diseased/normal thyroid tissue with univariate logistic regression analysis demonstrated that the area under the receiver operating characteristic curve for differentiating benign from malignant thyroid for the various phases of enhancement was greatest in the precontrast phase at 0.983 (95% CI, 0.954-1), with a cutoff value of ≤62 (sensitivity/specificity, 0.966/0.983) followed by the arterial phase.

CONCLUSIONS: Recurrent thyroid carcinoma can be distinguished from residual nonmalignant thyroid tissue using multiphasic multidetector CT with high accuracy. The maximum information for discrimination is in the precontrast images, then the arterial phase. An optimal clinical protocol could be built from any number of phases but should include a precontrast phase.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Debnam JM, Guha-Thakurta N, Sun J, et al. Distinguishing Recurrent Thyroid Cancer from Residual Nonmalignant Thyroid Tissue Using Multiphasic Multidetector CT. AJNR Am J Neuroradiol. 2020. PMID: 32327435. doi:10.3174/ajnr.A6519

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。