三阴性乳腺癌恶性超声特征的系统评价与Meta分析
该系统评价与Meta分析检索截至2019年11月的英文文献,纳入10项研究共620例患者,计算不同恶性超声特征诊断三阴性乳腺癌的汇总敏感度、特异度、似然比及AUC。结果显示各恶性超声特征的敏感度范围0.14-0.68、特异度范围0.19-0.66,AUC范围0.25-0.47,诊断价值低;阳性似然比范围0.4-0.9,阴性似然比范围1.09-2.02。结论认为三阴性乳腺癌缺乏乳腺癌典型恶性超声特征,有其自身超声特征。
要点
- 三阴性乳腺癌缺乏典型恶性超声特征,各特征诊断价值低(AUC范围0.25-0.47)。
- 各恶性超声特征敏感度范围0.14-0.68、特异度范围0.19-0.66,均不高。
- 阳性似然比范围0.4-0.9、阴性似然比范围1.09-2.02,确认或排除三阴性乳腺癌能力差。
核心结论
- 三阴性乳腺癌缺乏乳腺癌典型恶性超声特征,有其自身超声特征。
- 各恶性超声特征对三阴性乳腺癌的诊断价值低,AUC范围0.25-0.47。
- 各恶性超声特征确认或排除三阴性乳腺癌的能力差,阳性似然比范围0.4-0.9,阴性似然比范围1.09-2.02。
研究设计与样本
- 系统评价与Meta分析,全面检索截至2019年11月的英文文献。
- 纳入10项研究,共620例患者。
- 计算各恶性超声特征的汇总敏感度、特异度、阳性似然比、阴性似然比、诊断比值比及95%置信区间、SROC曲线和AUC。
诊断标准与关键数值
- 恶性超声特征包括形态不规则、边缘不清晰、高回声晕、非平行生长、后方声衰减、微钙化等。
- 各恶性超声特征敏感度范围0.14-0.68,特异度范围0.19-0.66。
- 各恶性超声特征AUC范围0.25-0.47,诊断价值低。
- 阳性似然比范围0.4-0.9,阴性似然比范围1.09-2.02。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The malignant ultrasound (US) features of breast cancer are known to include an irregular shape, a noncircumscribed margin, an echogenic halo, a nonparallel orientation, posterior acoustic attenuation, microcalcification, and others. However, these US features are uncertain and controversial for the diagnosis of triple-negative breast cancer (TNBC). This study aimed to analyze the diagnostic value of malignant US features for TNBC by a systematic review and meta-analysis, analyze the US characteristics of TNBC, and provide US evidence for clinical diagnosis.
METHODS: A comprehensive search was performed to identify relevant English articles concerning the US diagnosis of TNBC (from the date of database establishment to November 2019). The pooled sensitivity, pooled specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio with 95% confidence interval, summary receiver operating characteristic curve, and area under the curve for the different malignant US features were calculated.
RESULTS: Ten studies (620 patients) met the eligibility criteria. The sensitivity (range, 0.14-0.68) and specificity (range, 0.19-0.66) of the malignant US features were not high. Summary receiver operating characteristic curves showed that the area under the curve (range, 0.25-0.47) of the malignant US features was low, demonstrating that these features have poor diagnostic value for TNBC. The positive likelihood ratio (range, 0.4-to 0.9) of the malignant US features was low, and the negative likelihood ratio (range, 1.09-2.02) was not low, revealing that these features had a poor ability to confirm or exclude TNBC.
CONCLUSIONS: Triple-negative breast cancer lacks the typical malignant US features of breast cancer and has its own US features.
引用
- Tian L, Wang L, Qin Y, et al. Systematic Review and Meta-analysis of the Malignant Ultrasound Features of Triple-Negative Breast Cancer. J Ultrasound Med. 2020. PMID: 32339328. doi:10.1002/jum.15309
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。