二次超声能否降低MRI检出病灶的BI-RADS分级?一项回顾性研究
回顾性单中心纳入94例患者103个MRI检出、既往超声未发现的BI-RADS 4/5乳腺病灶,评估二次超声(SLU)检出率及特征。57个(55.3%)病灶被SLU检出,其中17个(29.8%)为恶性;所有SLU BI-RADS 2类病灶均为良性,理论上可避免30%的不必要活检,纳入BI-RADS 3类后升至60%,但出现1例(5.8%)假阴性。SLU可能将MRI偶发BI-RADS 4类病灶降级,从而减少30%–60%的不必要活检。
要点
- MRI检出而常规超声未见的BI-RADS 4/5病灶中,SLU可检出55.3%(57/103)。
- SLU检出的病灶中29.8%(17/57)为恶性,形态、方位、边缘、结构扭曲、高回声晕/水肿在良恶性间差异有统计学意义(p<0.05)。
- SLU BI-RADS 2类病灶均为良性,理论上可避免30%的不必要活检;纳入BI-RADS 3类后升至60%,但出现1例(5.8%)假阴性。
关键影像表现/征象
- SLU检出57个(55.3%)病灶,其中17个(29.8%)为恶性。
- SLU检出病灶在MRI上表现为肿块者占66.7%(38/57),非肿块者占33.3%(19/57)。
- 形态、方位、边缘、结构扭曲、高回声晕/水肿在SLU上区分良恶性差异有统计学意义(p<0.05)。
- SLU检出的3个BI-RADS 5类病灶均为恶性。
诊断标准与关键数值
- SLU BI-RADS 2类病灶均为良性,理论上可避免30%的不必要活检。
- 纳入SLU BI-RADS 3类病灶后,可避免活检比例升至60%,同时出现1例(5.8%,1/17)假阴性。
临床应用与阅片要点
- 对MRI检出而常规超声未见的BI-RADS 4/5病灶可行SLU,并依据SLU形态特征(形态、方位、边缘、结构扭曲、高回声晕/水肿)评估良恶性。
- SLU分类为BI-RADS 2类的病灶可能为良性,SLU BI-RADS 3类需权衡假阴性风险(本研究中1/17,5.8%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To determine whether MRI-detected suspicious (BIRADS 4 & 5) breast lesions can be downgraded using second-look ultrasound (SLU) and thus reduce unnecessarily performed breast biopsies.
MATERIALS METHODS: A retrospective single-center review of consecutive patients, who underwent breast MRI studies during a 12-month time period was performed. 94 patients with 103 lesions undergoing SLU of incidentally detected MRI BI-RADS 4&5 lesions which were not identified on previous ultrasound were included in the study. The SLU detection rate and SLU features of the lesions were assessed. Histology (91/103) or two year follow up (n = 12) were defined as the reference standard for lesion diagnosis.
RESULTS: 57 (55.3 %) of the 103 lesions were identified on SLU. 17 of the identified lesions were malignant (29.8 %). Lesions detected on ultrasound presented on MRI as masses in 66.7 % (38/57) and non-mass in 33.3 % (19/57). Our findings showed that it is possible to distinguish between malignant and benign lesions with SLU. The results were significant (p < 0.05) for the following morphological features: shape, orientation, margins, architectural distortion, hyperechoic rim/ edema. All lesions classified as SLU BI-RADS 2 in our study were benign and thus, 30 % of all unnecessary biopsies could potentially have been avoided. Including SLU BI-RADS 3 lesions, this rate increased to 60 %, while yielding one (of 17, 5.8 %) false negative result. All three BI-RADS 5 lesions detected by SLU presented as malignant on ultrasound.
CONCLUSION: SLU can potentially downgrade incidental MRI BIRADS 4 lesions. This may reduce the number of unnecessarily performed biopsies by 30-60 %, thus simplifying patient management.
引用
- Kolta M, Clauser P, Kapetas P, et al. Can second-look ultrasound downgrade MRI-detected lesions? A retrospective study. Eur J Radiol. 2020. PMID: 32339982. doi:10.1016/j.ejrad.2020.108976