自动乳腺超声:冠状面图像特征的观察者间一致性、诊断价值及相关临床因素
本研究纳入387例女性(共457个病理确诊病灶,含377个肿块和80个非肿块病变),评估自动乳腺超声冠状面特征(回缩现象、高/低回声环、跳跃征、白墙征)的观察者间一致性及其诊断价值;图像类型与各冠状面特征的总体观察者间一致性为中等至良好,回缩现象与恶性肿块显著相关,连续高或低回声环预测良性肿块,不连续环预测恶性肿块,跳跃征预测恶性非肿块病变。
要点
- 冠状面回缩现象与恶性肿块显著相关(p<0.001),更常见于小、表浅、低组织学分级浸润癌。
- 连续高或低回声环预测良性肿块(p<0.001),不连续环预测恶性肿块(p<0.001)。
- 非肿块病变中,跳跃征为恶性预测因子(p=0.040)。
关键影像表现/征象
- 冠状面回缩现象与恶性肿块显著相关(p<0.001)。
- 连续高或低回声环预测良性肿块(p<0.001),不连续环预测恶性肿块(p<0.001)。
- 高回声环更常见于距乳头较远的肿块(p=0.027),低回声环更常见于较大表浅肿块(p<0.001)。
- 非肿块病变中跳跃征为恶性预测因子(p=0.040)。
诊断标准与关键数值
- 457个病灶中296个恶性、161个良性。
- 图像类型与所有冠状面特征的总体观察者间一致性为中等至良好。
- 回缩现象与恶性肿块相关(p<0.001),更常见于小(p=0.027)、表浅(p=0.002)、低组织学分级(p<0.001)的浸润癌。
- 连续高或低回声环预测良性肿块(p<0.001),不连续环预测恶性肿块(p<0.001)。
- 非肿块病变中跳跃征预测恶性(p=0.040)。
临床应用与阅片要点
- 阅片时可关注冠状面回缩现象、高/低回声环连续性及跳跃征,辅助鉴别乳腺病变良恶性。
- 高回声环更常见于距乳头较远肿块,低回声环更常见于较大表浅肿块,判读时结合病灶位置与大小。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the interobserver agreement, diagnostic value, and associated clinical factors of automated breast ultrasound (ABUS) coronal features in differentiating breast lesions.
MATERIALS AND METHODS: This study enrolled 457 pathologically confirmed lesions in 387 female (age, 46.4 ± 10.3 years), including 377 masses and 80 non-mass lesions (NMLs). The unique coronal features, including retraction phenomenon, hyper- or hypoechoic rim (continuous or discontinuous), skipping sign, and white wall sign, were defined and recorded. The interobserver agreement on image type and coronal features was evaluated. Furthermore, clinical factors, including the lesion size, distance to the nipple or skin, palpability, and the histological grade were analyzed.
RESULTS: Among the 457 lesions, 296 were malignant and 161 were benign. The overall interobserver agreement for image type and all coronal features was moderate to good. For masses, the retraction phenomenon was significantly associated with malignancies (p < 0.001) and more frequently presented in small and superficial invasive carcinomas with a low histological grade (p = 0.027, 0.002, and < 0.001, respectively). Furthermore, continuous hyper- or hypoechoic rims were predictive of benign masses (p < 0.001), whereas discontinuous rims were predictive of malignancies (p < 0.001). A hyperechoic rim was more commonly detected in masses more distant from the nipple (p = 0.027), and a hypoechoic rim was more frequently found in large superficial masses (p < 0.001 for both). For NMLs, the skipping sign was a predictor of malignancies (p = 0.040).
CONCLUSION: The coronal plane of ABUS may provide useful diagnostic value for breast lesions.
引用
- Tang G, An X, Xiang H, et al. Automated Breast Ultrasound: Interobserver Agreement, Diagnostic Value, and Associated Clinical Factors of Coronal-Plane Image Features. Korean J Radiol. 2020. PMID: 32323500. doi:10.3348/kjr.2019.0525
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。