单侧乳腺症状男性患者:一种最佳影像学方法
研究纳入271例单侧乳腺症状男性患者行双侧乳腺X线摄影,分别进行单侧与双侧阅片比较诊断效能,并分析超声结果与平均腺体剂量。单侧与双侧阅片的AUC分别为0.966与0.962(p=0.415),诊断效能相当;单侧阅片可减少辐射暴露。
要点
- 单侧与双侧乳腺X线摄影阅片在男性单侧乳腺症状患者中诊断效能相当。
- 单侧阅片AUC为0.966,双侧阅片AUC为0.962(p=0.415)。
- 单侧乳腺X线摄影可减少辐射暴露,平均腺体剂量症状侧1.10±0.29 mGy vs 对侧1.04±0.30 mGy(p<0.001)。
核心结论
- 在单侧乳腺症状男性患者中,单侧乳腺X线摄影的诊断效能与双侧乳腺X线摄影相当,且单侧摄影具有减少辐射暴露的优势。
研究设计与样本
- 研究纳入271例连续的单侧乳腺症状男性患者(平均年龄57岁),均行双侧乳腺X线摄影。
- 图像解读采用改良BI-RADS量表(1至5分),先进行症状侧乳腺单侧阅片,再进行双侧阅片,比较两种阅片的诊断效能。
- 记录对侧乳腺异常及每次曝光的平均腺体剂量,并分析超声结果与乳腺X线摄影进行比较。
关键影像表现/征象
- 271例男性患者中,29例经病理诊断为乳腺癌,无一例双侧乳腺癌。
- 对侧乳腺异常及每次曝光的平均腺体剂量被记录,症状侧平均腺体剂量为1.10±0.29 mGy,对侧为1.04±0.30 mGy(p<0.001)。
诊断标准与关键数值
- 单侧阅片的敏感度、特异度、阳性预测值、阴性预测值和准确率分别为96.6%、96.7%、77.8%、99.6%和96.7%。
- 双侧阅片的敏感度、特异度、阳性预测值、阴性预测值和准确率分别为96.6%、95.9%、73.7%、99.6%和95.9%。
- 受试者工作特征分析显示两种方法诊断效能均优秀:单侧阅片AUC为0.966,双侧阅片AUC为0.962(p=0.415)。
- 超声的诊断效能参数与乳腺X线摄影双侧或单侧阅片相比无显著差异。
临床应用与阅片要点
- 对于单侧乳腺症状的男性患者,单侧乳腺X线摄影的诊断效能与双侧摄影相当,且可减少辐射暴露。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the usefulness of bilateral mammography in male patients with unilateral breast symptoms, including investigation of the diagnostic performance of unilateral and bilateral reviews and the average glandular dose (AGD) per exposure.
METHODS: Two hundred seventy-one consecutive male patients (mean age, 57 years) with unilateral breast symptoms underwent bilateral mammography. Image interpretation was performed in two ways, first with a unilateral review of the symptomatic breast and then with a bilateral review. A modified BI-RADS scale (from 1 to 5) was used. The diagnostic performance of unilateral and bilateral reviews was compared, and contralateral breast abnormalities and the AGD per exposure were recorded. We also analyzed ultrasound (US) results and compared them with mammography.
RESULTS: Of 271 male patients, 29 were pathologically diagnosed with breast cancer. There was no bilateral breast cancer. The sensitivity, specificity, positive and negative predictive values, and accuracy were 96.6%, 96.7%, 77.8%, 99.6%, and 96.7%, respectively, for unilateral review, and 96.6%, 95.9%, 73.7%, 99.6%, and 95.9% for bilateral review. Receiver operator characteristic analysis showed excellent diagnostic performance for both methods: the area under the curve (AUC) was 0.966 for unilateral review and 0.962 for bilateral review (p = 0.415). The mean AGD per exposure was 1.10 ± 0.29 mGy for symptomatic breast and 1.04 ± 0.30 mGy for contralateral breast (p < 0.001). Diagnostic performance parameters of US were not significantly different from bilateral or unilateral review of mammography.
CONCLUSION: The diagnostic performance of unilateral mammography is comparable with bilateral mammography in male patients with unilateral breast symptoms. Unilateral mammography also has the advantage of reducing radiation exposure.
KEY POINTS: • There is limited knowledge about standardized guidelines or recommendations for imaging the male breast. • Unilateral mammography for male patients with unilateral breast symptoms showed comparable diagnostic performance with bilateral mammography. • Both unilateral and bilateral mammography showed excellent diagnostic performance in the assessment of male patients with unilateral breast symptoms.
引用
- Yoon B, Chae EY, Cha JH, et al. Male patients with unilateral breast symptoms: an optimal imaging approach. Eur Radiol. 2020. PMID: 32242274. doi:10.1007/s00330-020-06828-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。