文献速递乳腺MR

乳腺癌在计算与采集高b值扩散加权MRI上的可见度比较

Breast Cancer Conspicuity on Computed Versus Acquired High b-Value Diffusion-Weighted MRI.
PubMed 文献 · Acad Radiol · 2020-04-16

前瞻性纳入30例新诊断乳腺癌女性,行3T乳腺MRI扩散加权成像,比较计算与采集高b值图像的病灶对比噪声比及阅片者可见度。采集图像对比噪声比略高于计算图像(p=0.018),但阅片者评估的病灶可见度无差异(p=0.36);阅片者选择的最佳b值(平均1411±383 s/mm²)略高于峰值对比噪声比对应b值(1233±463 s/mm²,p=0.023)。

要点

  • 采集高b值图像病灶对比噪声比略高于计算图像(p=0.018),但阅片者可见度评估无显著差异(p=0.36)。
  • 阅片者选择的最佳b值平均为1411±383 s/mm²,略高于峰值对比噪声比对应的1233±463 s/mm²(p=0.023)。
  • 年轻(≤50岁)及致密型乳腺女性的最佳b值更高(分别p=0.002、p=0.015)。

核心结论

  • 计算高b值图像病灶对比噪声比略低于采集图像,但本研究提示这未显著影响病灶可见度;计算高b值图像为阅片时调整b值提供了额外灵活性。

研究设计与样本

  • 前瞻性研究,纳入30例新诊断乳腺癌女性(中位年龄48岁;28例浸润性癌,2例导管原位癌),行3T乳腺MRI扩散加权成像。
  • 在0-2500 s/mm²范围内测量计算与采集扩散加权图像的病灶对比噪声比;由3名阅片者独立比较两种图像的病灶可见度并选择最佳b值。
  • 计算与采集图像定量比较采用配对t检验,定性比较采用符号检验;最佳b值与临床特征的关联采用Wilcoxon秩和检验。

诊断标准与关键数值

  • 采集图像病灶对比噪声比高于计算图像(p=0.018)。
  • 阅片者评估的病灶可见度在计算与采集图像间无差异(p=0.36)。
  • 阅片者选择的最佳b值平均为1411±383 s/mm²,高于峰值对比噪声比对应的b值1233±463 s/mm²(p=0.023)。
  • 最佳b值在年轻(≤50岁)与年长女性间比较p=0.002,在致密型与非致密型乳腺间比较p=0.015,均为前者更高。

临床应用与阅片要点

  • 计算高b值图像可在阅片时灵活调整b值,本研究提示其病灶可见度与采集图像无显著差异,但对比噪声比略低。
  • 年轻(≤50岁)及致密型乳腺女性可能需要更高的最佳b值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: On unenhanced diffusion-weighted imaging (DWI), computing or synthesizing high b-value images from lower b-value acquisitions can enhance breast cancer visibility. This study aimed to evaluate relative lesion conspicuity on computed versus acquired diffusion-weighted images and investigate clinical characteristics influencing optimal b-values.

MATERIALS AND METHODS: Women with newly diagnosed breast cancer were prospectively enrolled and underwent 3T breast MRI with DWI. Lesion contrast-to-noise ratio (CNR) was measured across a range of b-values (0-2500 s/mm2) for computed and acquired DWI. Three readers independently compared lesion visibility between computed and acquired DWI and selected the optimal b-value. Computed versus acquired DWI was compared quantitatively based on CNR by paired t-test and qualitatively based on reader preference using a sign test. Optimal b-values by qualitative and quantitative assessment were compared by paired t-test, and associations with clinical characteristics were assessed by Wilcoxon rank sum test.

RESULTS: The study included 30 women (median age, 48 years); 28 with invasive carcinoma, 2 DCIS. Lesion CNR was higher on acquired versus computed images (p = 0.018), while lesion visibility by reader assessment was not different (p = 0.36). Optimal b-values selected by readers (mean, b = 1411 ± 383 s/mm2) were slightly higher than those based on peak CNR (b = 1233 ± 463 s/mm2, p = 0.023), and were higher for younger (≤50 years) versus older women (p = 0.002) and dense versus nondense breasts (p = 0.015).

CONCLUSION: Lesion CNR on computed high b-value images was slightly reduced versus acquired images, but our study suggests that this did not significantly impact lesion visibility. Computing high b-value images offers extra flexibility to adjust b-value during interpretation.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. DelPriore MR, Biswas D, Hippe DS, et al. Breast Cancer Conspicuity on Computed Versus Acquired High b-Value Diffusion-Weighted MRI. Acad Radiol. 2020. PMID: 32307271. doi:10.1016/j.acra.2020.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。