英国超过1100万例分娩的死产趋势未提供证据支持成长评估方案项目的有效性
结果显示两地区死产率均自2010年后下降,但GAP实施较少的苏格兰下降更快,提示不能以英格兰/威尔士的死产率下降推断GAP的有效性。
要点
- 研究期间苏格兰单胎分娩870632例、死产4243例,英格兰与威尔士单胎分娩10469120例、死产51562例。
- 2015年死产率苏格兰为3.75/1000(95%CI 3.25-4.30),英格兰与威尔士为4.30/1000(95%CI 4.15-4.46)。
- 2010年至2015年苏格兰死产率下降速度较英格兰与威尔士更快,每10万例分娩减少48例(95%CI 47.9-48.1)。
诊断标准与关键数值
- 死产率按每1000例分娩计算,按分娩年份统计,并比较苏格兰与英格兰/威尔士。
- 2015年死产率苏格兰3.75/1000(95%CI 3.25-4.30),英格兰与威尔士4.30/1000(95%CI 4.15-4.46)。
- 2010年至2015年与2000年至2009年相比,苏格兰每10万例分娩的死产数较英格兰与威尔士减少48例(95%CI 47.9-48.1)。
临床应用与阅片要点
- 作者认为,英格兰与威尔士死产率随时间的变化不能用于推断GAP项目的有效性。
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Use of the Growth Assessment Protocol (GAP) has increased internationally under the assumption that it reduces the stillbirth rate. The evidence for this is limited and based largely on an ecological time-trend study. Discordance in the uptake of the GAP program between Scotland and England/Wales enabled us to assess the assertion that implementation of GAP leads to a reduced stillbirth rate.
METHODS: We analyzed data from the National Records for Scotland and the Office for National Statistics on the number of singleton maternities and stillbirths in Scotland and in England and Wales, respectively, from 1 January 2000 to 31 December 2015. National uptake of the GAP program over time in each of the regions was recorded. Stillbirth rate per 1000 maternities was calculated, according to year of delivery, and compared between Scotland and England/Wales.
RESULTS: During the study period, there were 870 632 singleton maternities in Scotland, of which 4243 were stillbirths, and there were 10 469 120 singleton maternities in England and Wales, of which 51 562 were stillbirths. There was a marked difference in uptake of the GAP program between the two regions, with substantially fewer maternity units in Scotland implementing the program. Stillbirth rates were static up to 2010, with a decline thereafter in both regions, to 3.75 (95% CI, 3.25-4.30) per 1000 maternities in Scotland and 4.30 (95% CI, 4.15-4.46) per 1000 maternities in England and Wales in 2015. From 2010 onwards, the decline in Scotland was faster, equating to 48 (95% CI, 47.9-48.1) fewer stillbirths per 100 000 maternities in Scotland than in England and Wales from 2010 to 2015 compared with 2000 to 2009.
CONCLUSIONS: We observed a decline in stillbirth rate in England and Wales, which coincided with implementation of the GAP program. However, a concurrent decline in stillbirth rate was observed in Scotland in the absence of increased implementation of GAP. The secular rates of change in stillbirth rate in England and Wales cannot be used to infer efficacy of the GAP program. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Iliodromiti S, Smith GCS, Lawlor DA, et al. UK stillbirth trends in over 11 million births provide no evidence to support effectiveness of Growth Assessment Protocol program. Ultrasound Obstet Gynecol. 2020. PMID: 32266750. doi:10.1002/uog.21999
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。