双能CT能否鉴别卵巢肿瘤的良性与恶性
回顾性纳入37例初治卵巢肿瘤患者(良性11例、恶性26例,其中高级别20例、低级别6例),利用术前双能CT测量50、70、120 keV的CT衰减值、有效原子序数、水含量和碘含量。恶性组有效原子序数和碘含量显著高于良性组;高级别组水含量显著高于低级别组。双能CT可能有助于鉴别卵巢肿瘤良恶性并预测肿瘤分级。
要点
- 碘含量≥9.74(100 μg/cm3)诊断恶性卵巢肿瘤的敏感度81%、特异度73%。
- 有效原子序数≥8.16诊断恶性卵巢肿瘤的敏感度85%、特异度73%。
- 水含量≥1,013.92 mg/cm3鉴别高级别与低级别恶性肿瘤的敏感度80%、特异度83%。
核心结论
- 双能CT可能有助于鉴别卵巢肿瘤的良性与恶性,并预测肿瘤分级。
研究设计与样本
- 经机构审查委员会批准后,从机构数据库检索接受初次肿瘤细胞减灭术的初治卵巢肿瘤患者,共纳入37例,分为良性卵巢肿瘤11例与恶性卵巢肿瘤26例,恶性中高级别20例、低级别6例。
- 在术前分期双能CT检查上使用Advantage Workstation对卵巢肿块进行高级处理和感兴趣区勾画。
- 记录卵巢肿块在50、70、120 keV的CT衰减值像素级数据以及有效原子序数、水含量和碘含量。
诊断标准与关键数值
- 恶性卵巢肿瘤的碘含量显著高于良性卵巢肿瘤;诊断恶性卵巢肿瘤的阈值为碘含量≥9.74(100 μg/cm3),敏感度81%、特异度73%。
- 恶性卵巢肿瘤的有效原子序数显著高于良性卵巢肿瘤;诊断恶性卵巢肿瘤的阈值为有效原子序数≥8.16,敏感度85%、特异度73%。
- 高级别卵巢肿瘤的水含量显著高于低级别卵巢肿瘤;鉴别两者的阈值为水含量≥1,013.92 mg/cm3,敏感度80%、特异度83%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess the ability of dual-energy computed tomography (DECT) to distinguish benign from malignant ovarian tumours (OTs).
MATERIALS AND METHODS: Following approval of the institutional review board, the institutional database was mined for treatment-naive patients who underwent primary cytoreduction for OT. Thirty-seven patients were included and divided into those with benign OTs (n = 11) and malignant OTs (n = 26), including high-grade (n = 20) and low-grade (n = 6) malignant OTs. Advanced processing and region of interest delineation on the ovarian mass were performed using the preoperative staging DECT examination using the Advantage Workstation. The pixel-level data of the CT attenuation values at 50, 70, and 120 keV and the effective atomic number (Zeff), water content (WC), and iodine content (IC) in the ovarian mass were recorded. The Wilcoxon rank-sum test was used to compare CT attenuation data at different voltages, Zeff, and WC and IC levels between benign and malignant OTs and between high- and low-grade malignant OTs. Simple logistic regression was used to correlate the imaging characteristics with malignant status and grade.
RESULTS: Malignant OTs had significantly higher Zeff and IC compared with benign OTs. The threshold values for the diagnosis of malignant OT were IC≥9.74 (100 μg/cm3) with 81% sensitivity and 73% specificity and Zeff ≥8.16 with 85% sensitivity and 73% specificity. High-grade OTs had significantly higher WC compared with low-grade OTs, and a threshold of ≥1,013.92 mg/cm3 differentiated them with 80% sensitivity and 83% specificity.
CONCLUSION: DECT may be a tool to help distinguish malignant and benign OTs and predict tumour grade.
引用
- Elsherif SB, Zheng S, Ganeshan D, et al. Does dual-energy CT differentiate benign and malignant ovarian tumours? Clin Radiol. 2020. PMID: 32252992. doi:10.1016/j.crad.2020.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。