慢性血液透析患者正中神经的剪切波速度测量
研究纳入25例每周透析3次的慢性肾脏病血液透析患者和26例健康对照,均无美国神经病学学会实践参数标准定义的腕管综合征症状或体征,比较两组双手正中神经的横截面积和剪切波速度。血液透析组平均横截面积及纵向、轴向剪切波速度均显著高于对照组,提示剪切波超声弹性成像可检测慢性血液透析患者正中神经的结构改变。
要点
- 血液透析患者正中神经平均横截面积显著高于健康对照(12.74 ± 1.88 mm² 对 8.89 ± 1.45 mm²,P < .001)。
- 血液透析组纵向和轴向剪切波速度均显著高于对照组(P < .001)。
- 剪切波超声弹性成像可检测慢性血液透析患者正中神经的结构改变。
关键影像表现/征象
- 血液透析组正中神经平均横截面积显著高于对照组(12.74 ± 1.88 mm² 对 8.89 ± 1.45 mm²,P < .001)。
- 血液透析组平均纵向剪切波速度显著高于对照组(3.86 ± 0.54 m/s 对 2.98 ± 0.31 m/s,P < .001)。
- 血液透析组平均轴向剪切波速度显著高于对照组(3.92 ± 0.52 m/s 对 3.04 ± 0.31 m/s,P < .001)。
诊断标准与关键数值
- 腕管综合征症状或体征按美国神经病学学会实践参数标准判定,所有参与者均无这些表现。
- 血液透析组正中神经平均横截面积为12.74 ± 1.88 mm²,对照组为8.89 ± 1.45 mm²(P < .001)。
- 血液透析组平均纵向剪切波速度为3.86 ± 0.54 m/s,对照组为2.98 ± 0.31 m/s(P < .001)。
- 血液透析组平均轴向剪切波速度为3.92 ± 0.52 m/s,对照组为3.04 ± 0.31 m/s(P < .001)。
临床应用与阅片要点
- 在无腕管综合征症状或体征的慢性血液透析患者中,正中神经横截面积和剪切波速度可高于健康对照。
- 剪切波超声弹性成像可用于检测慢性血液透析患者正中神经的结构改变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Chronic dialysis causes changes in the structure of median nerve. This is a risk for the development of carpal tunnel syndrome in patients on dialysis. The aim of the present study was to evaluate the diagnostic capacity of shear wave velocity (SWV) and the cross-sectional area (CSA) to detect the structural changes of the median nerve in patients with end-stage chronic kidney disease on hemodialysis.
METHODS: Twenty-five patients with chronic kidney disease undergoing hemodialysis 3 times per week and 26 healthy controls were included. None of the participants had any signs or symptoms of carpal tunnel syndrome specified according to the criteria of the American Academy of Neurology Practice Parameters. Both patients and controls underwent sonographic and elastographic examinations of the median nerves in both hands to evaluate CSA and SWV values, and they were compared regarding these parameters.
RESULTS: The mean CSA of the median nerve in the chronic hemodialysis group was significantly higher than that in the control group (12.74 ± 1.88 mm2 versus 8.89 ± 1.45 mm2 ; P < .001). The mean longitudinal and axial SWV values in the hemodialysis group (3.86 ± 0.54 m/s and 3.92 ± 0.52 m/s, respectively) were significantly higher than those in the control group (2.98 ± 0.31 m/s and 3.04 ± 0.31 m/s, respectively; P < .001).
CONCLUSIONS: Patients on chronic hemodialysis had higher mean CSA and SWV values of the median nerve compared with the healthy controls. Structural changes in the median nerve that occur in patients on chronic hemodialysis can be detected by shear-wave sonoelastography.
引用
- Yalçın K, Çakar Demir B. Shear Wave Velocity Measurements of the Median Nerve in Patients on Chronic Hemodialysis. J Ultrasound Med. 2020. PMID: 32249947. doi:10.1002/jum.15275
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。