化学交换饱和转移与磁化转移MRI在3T动物模型中检测肾纤维化代谢与结构改变的作用
本研究在3T MRI上联合化学交换饱和转移(CEST)与常规磁化转移成像(MT),评估单侧输尿管结扎(UUO)大鼠肾纤维化的代谢与结构改变。35只Sprague-Dawley大鼠分为UUO手术组(n=25)和假手术组(n=10),术后第1、3、5、7天对梗阻肾与对侧肾行CEST和MT检查,并行18F-FDG PET量化葡萄糖代谢,组织学及Western blot测纤维化。结果显示CEST的MTRasym(1.2ppm)与MT的MTR可提供代谢与结构信息,MTRasym(1.2ppm)与SUVmax呈负相关(r=-0.350,p=0.021),MTR与α-SMA呈强负相关(r=-0.744,p<0.001)。
要点
- UUO大鼠肾皮质及髓质的MTRasym(1.2ppm)与MTR在术后第3、7天与对侧肾差异显著(p<0.05)。
- 术后第7天UUO肾皮质及髓质的MTRasym(1.2ppm)与MTR与假手术肾差异显著(p<0.05)。
- UUO肾髓质MTRasym(1.2ppm)与SUVmax呈负相关(r=-0.350,p=0.021)。
关键影像表现/征象
- 术后第3、7天UUO肾皮质及髓质的MTRasym(1.2ppm)与MTR均与对侧肾差异显著(p<0.05)。
- 术后第7天UUO肾皮质及髓质的MTRasym(1.2ppm)与MTR均与假手术肾差异显著(p<0.05)。
诊断标准与关键数值
- CEST来源的MTRasym(1.2ppm)与SUVmax在UUO肾髓质呈负相关(r=-0.350,p=0.021)。
- MT来源的MTR与α-SMA在UUO肾髓质呈强负相关(r=-0.744,p<0.001)。
临床应用与阅片要点
- CEST的MTRasym(1.2ppm)可反映UUO肾髓质葡萄糖代谢变化,与SUVmax负相关(r=-0.350,p=0.021)。
- MT的MTR可反映UUO肾髓质纤维化结构改变,与α-SMA强负相关(r=-0.744,p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the value of combined chemical exchange saturation transfer (CEST) and conventional magnetization transfer imaging (MT) in detecting metabolic and structural changes of renal fibrosis in rats with unilateral ureteral obstruction (UUO) at 3T MRI.
MATERIALS AND METHODS: Thirty-five Sprague-Dawley rats underwent UUO surgery (n = 25) or sham surgery (n = 10). The obstructed and contralateral kidneys were evaluated on days 1, 3, 5, and 7 after surgery. After CEST and MT examinations, 18F-labeled fluoro-2-deoxyglucose positron emission tomography was performed to quantify glucose metabolism. Fibrosis was measured by histology and western blots. Correlations were compared between asymmetrical magnetization transfer ratio at 1.2 ppm (MTRasym(1.2ppm)) derived from CEST and maximum standard uptake value (SUVmax) and between magnetization transfer ratio (MTR) derived from MT and alpha-smooth muscle actin (α-SMA).
RESULTS: On days 3 and 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of contralateral kidneys (p < 0.05). On day 7, MTRasym(1.2ppm) and MTR of UUO renal cortex and medulla were significantly different from those of sham-operated kidneys (p < 0.05). The MTRasym(1.2ppm) of UUO renal medulla was fairly negatively correlated with SUVmax (r = -0.350, p = 0.021), whereas MTR of UUO renal medulla was strongly negatively correlated with α-SMA (r = -0.744, p < 0.001).
CONCLUSION: CEST and MT could provide metabolic and structural information for comprehensive assessment of renal fibrosis in UUO rats in 3T MRI and may aid in clinical monitoring of renal fibrosis in patients with chronic kidney disease.
引用
- Li A, Xu C, Liang P, et al. Role of Chemical Exchange Saturation Transfer and Magnetization Transfer MRI in Detecting Metabolic and Structural Changes of Renal Fibrosis in an Animal Model at 3T. Korean J Radiol. 2020. PMID: 32323504. doi:10.3348/kjr.2019.0646
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。