文献速递腹部泌尿生殖CT

双能CT虚拟平扫重建中优化肾结石检测的协议分析

Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions.
PubMed 文献 · Eur Radiol · 2020-04-03

本研究为前瞻性体模研究,将16枚不同大小(1.2-4.5 mm)和成分的肾结石置于肾脏体模中,行72次双能CT扫描(不同管电压组合及碘浓度),由两名放射科医生独立评估结石检出。结果显示,大于2 mm结石检出率显著高于小于2 mm结石(84.7% vs 12.7%,p<0.001);在对比剂衰减≤600 HU时,70 kV/Sn 150 kV和80 kV/Sn 150 kV协议敏感度分别达99.6%和96.0%。

要点

  • 虚拟平扫检出率高度依赖肾盂周围对比剂衰减,衰减>600 HU时易掩盖输尿管结石。
  • 较低管电压协议(70 kV/Sn 150 kV和80 kV/Sn 150 kV)可提高虚拟平扫肾结石检出率。
  • 虚拟平扫对直径≤2 mm结石检出率显著降低,阅片时需警惕小结石漏诊。

核心结论

  • 双能CT虚拟平扫中,较低管电流和较低对比剂衰减的扫描协议对大于2 mm结石检出效果优异,但对小结石存在局限。

研究设计与样本

  • 前瞻性体模研究,将16枚不同大小(1.2-4.5 mm)和成分(鸟粪石、胱氨酸、草酸钙、透钙磷石)的肾结石置于肾脏体模中,行72次双能CT扫描,使用9种不同碘对比剂/盐水溶液(衰减0-1400 HU)及不同管电压设置(70 kV/150 kV、80 kV/150 kV、90 kV/150 kV、100 kV/150 kV),由两名经验丰富的放射科医生独立评估。

诊断标准与关键数值

  • 分类树分析显示,直径>2 mm结石检出率为84.7%,直径<2 mm结石检出率为12.7%(p<0.001);直径>2 mm结石在70 kV/Sn 150 kV和80 kV/Sn 150 kV协议、对比剂衰减≤600 HU时敏感度分别为99.6%和96.0%;管腔内衰减>600 HU时检出率显著降低(0-600 HU为91.8%,900-1400 HU为70.7%,p<0.001);本研究中胱氨酸结石检出率最佳。

临床应用与阅片要点

  • 阅片时应关注肾盂周围对比剂衰减,尽量控制在≤600 HU以避免掩盖输尿管结石;对≤2 mm结石需结合其他重建或序列谨慎判断。

局限性

  • 本研究为体模研究,结果需进一步临床验证。
  • 虚拟平扫对小于2 mm结石检出率显著降低,存在局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Previous studies have shown that split-bolus protocols in virtual non-contrast (VNC) reconstructions of dual-energy computed tomography (DE-CT) significantly decrease radiation dose in patients with urinary stone disease. To evaluate the impact on kidney stone detection rate of stone composition, size, tube voltage, and iodine concentration for VNC reconstructions of DE-CT.

METHODS: In this prospective study, 16 kidney stones of different sizes (1.2-4.5 mm) and compositions (struvite, cystine, whewellite, brushite) were placed within a kidney phantom. Seventy-two scans with nine different iodine contrast agents/saline solutions with increasing attenuation (0-1400 HU) and different kilovoltage settings (70 kV/150 kV; 80 kV/150 kV; 90 kV/150 kV; 100 kV/150 kV) were performed. Two experienced radiologists independently rated the images for the presence and absence of stones. Multivariate classification tree analysis and descriptive statistics were used to evaluate the diagnostic performance.

RESULTS: Classification tree analysis revealed a higher detection rate of renal calculi > 2 mm in size compared with that of renal calculi < 2 mm (84.7%; 12.7%; p < 0.001). For stones with a diameter > 2 mm, the best results were found at 70 kV/Sn 150 kV and 80 kV/Sn 150 kV in scans with contrast media attenuation of 600 HU or less, with sensitivity of 99.6% and 96.0%, respectively. A higher luminal attenuation (> 600 HU) resulted in a significantly decreased detection rate (91.8%, 0-600 HU; 70.7%, 900-1400 HU; p < 0.001). In our study setup, the detection rates were best for cystine stones.

CONCLUSION: Scan protocols in DE-CT with lower tube current and lower contrast medium attenuation show excellent results in VNC for stones larger than 2 mm but have limitations for small stones.

KEY POINTS: • The detection rate of virtual non-contrast reconstructions is highly dependent on the surrounding contrast medium attenuation at the renal pelvis and should be kept as low as possible, as at an attenuation higher than 600 HU the VNC reconstructions are susceptible to masking ureteral stones. • Protocols with lower tube voltages (70 kV/Sn 150 kV and 80 kV/Sn 150 kV) improve the detection rate of kidney stones in VNC reconstructions. • The visibility of renal stones in virtual non-contrast of dual-energy CT is highly associated with the size, and results in a significantly lower detection rate in stones below 2 mm.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lazar M, Ringl H, Baltzer P, et al. Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions. Eur Radiol. 2020. PMID: 32242275. doi:10.1007/s00330-020-06806-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。