文献速递泌尿生殖US

睾丸剪切波弹性成像:硬度值在多种常见睾丸疾病中的潜在作用

Shear-wave elastography of the testicle: potential role of the stiffness value in various common testicular diseases.
PubMed 文献 · Clin Radiol · 2020-04-02

本研究对338例患者的正常睾丸(358个)、睾丸微石症(40个)及多种睾丸疾病(208个)行实时剪切波弹性成像,记录硬度值并与临床、长期随访或组织病理学诊断对照。正常睾丸平均杨氏模量为4.55±2.54 kPa,肿瘤性病变中位硬度21.02 kPa(截断值16.1 kPa),纤维化中位硬度30.03 kPa(截断值26.3 kPa),两者差异有统计学意义(p=0.001)。结论认为剪切波弹性成像可用于区分睾丸纤维化与肿瘤性病变。

要点

  • 正常睾丸平均杨氏模量为4.55±2.54 kPa,可作为基线参考。
  • 睾丸肿瘤性病变中位硬度21.02 kPa,截断值16.1 kPa。
  • 睾丸纤维化中位硬度30.03 kPa,截断值26.3 kPa,高于肿瘤性病变。

核心结论

  • 剪切波弹性成像可用于探查睾丸实质,其硬度值能区分睾丸纤维化与肿瘤性病变。

研究设计与样本

  • 对338例患者(平均年龄43.2±17.2岁,范围17-78岁)行实时剪切波弹性成像,包括正常睾丸358个、睾丸微石症40个及多种睾丸疾病208个。
  • 最终诊断结合临床情况、长期随访或组织病理学。
  • 统计评估旨在提供病理诊断的硬度阈值。

关键影像表现/征象

  • 正常睾丸平均杨氏模量为4.55±2.54 kPa。
  • 睾丸病变平均大小为2.6±1.5 cm(范围10-42 mm)。
  • 无论微石症处于何阶段,均记录到统计学显著更高的硬度值。
  • 急性睾丸炎平均硬度值略高,但无统计学显著差异。

诊断标准与关键数值

  • 睾丸肿瘤性病变中位硬度值为21.02 kPa,截断值16.1 kPa。
  • 纤维化中位硬度值最高,为30.03 kPa,截断值26.3 kPa。
  • 纤维化与肿瘤性病变之间差异有统计学意义(p=0.001)。

临床应用与阅片要点

  • 剪切波弹性成像可用于探查睾丸实质,硬度值有助于区分纤维化与肿瘤性病变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the value and efficacy of real-time shear-wave elastography (SWE) of normal testicular parenchyma and various common testicular diseases in clinical practice.

MATERIALS AND METHODS: SWE was undertaken in 338 patients (mean age: 43.2±17.2 years, range 17-78 years) comprising normal testicles (n = 358), testicular microlithiasis (n = 40), and various testicular diseases (n = 208) and the stiffness was recorded. The final diagnosis was correlated with the clinical context, long-term follow-up, or histopathology. Statistical evaluation was performed to provide a stiffness threshold for pathological diagnosis.

RESULTS: The mean size of testicular lesions was 2.6±1.5 cm (range: 10-42 mm). The mean Young's modulus value for normal testis was recorded at 4.55±2.54 kPa. Whatever the stage of microlithiasis, a higher statistically significant stiffness value was recorded. For acute orchitis, the mean stiffness value was slightly higher, but not statistically significantly. The testicular tumoural processes presented a median stiffness value of 21.02 kPa with a cut-off of 16.1 kPa. Fibrosis presented the highest median stiffness value of 30.03 kPa with a cut-off of 26.3 kPa. By analysing the distribution of the different pathological groups, the difference was statistically significant between fibrosis and tumoural processes (p = 0.001).

CONCLUSION: SWE is a feasible technique in the exploration of the testicular parenchyma. SWE values can be used to differentiate testicular fibrosis from a tumoural process with confidence.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Roy C, de Marini P, Labani A, et al. Shear-wave elastography of the testicle: potential role of the stiffness value in various common testicular diseases. Clin Radiol. 2020. PMID: 32248949. doi:10.1016/j.crad.2020.02.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。