超微血管成像技术提高对不确定性肾脏肿块血管性的检测

Superb Microvascular Imaging Improves Detection of Vascularity in Indeterminate Renal Masses.
PubMed 文献 · J Ultrasound Med · 2020-04-20

本研究比较了超微血管成像(SMI)与标准彩色多普勒成像(CDI)和能量多普勒成像(PDI)在检测不确定性肾脏肿块(iRM)内血管性方面的效用,以超声造影(CEUS)为参考标准。结果显示,与其它3种模式相比,单色SMI(mSMI)敏感度最高(63.3%),彩色SMI(cSMI)特异度最高(62.1%),cSMI和mSMI诊断准确率最高(分别为0.678和0.680,均P < 0.001)。结论提示SMI可能是检测iRM微血管的有用方法,未来研究应比较SMI与CEUS的效能并评估SMI鉴别iRM恶性的能力。

要点

  • 单色SMI检测iRM血管性的敏感度最高(63.3%),彩色SMI特异度最高(62.1%)。
  • 彩色SMI和单色SMI诊断准确率最高(分别为0.678和0.680,均P < 0.001),高于CDI(0.568)和PDI(0.555)。
  • 单色SMI的读者诊断信心(均值±标准差,3.6±1.1)显著低于CDI(4.1±1.0)和PDI(4.0±1.0)(P < 0.001)。

核心结论

  • 初步数据提示,与标准多普勒技术相比,SMI可能是检测不确定性肾脏肿块微血管的有用方法。

研究设计与样本

  • 研究纳入因不确定性肾脏肿块接受超声造影(CEUS)评估的患者,先使用Aplio i800扫描仪和i8CX1探头(Canon Medical Systems)行肾脏超声检查,模式包括CDI、PDI、彩色SMI(cSMI)和单色SMI(mSMI);图像随机化后由4名盲法读者按1至5分诊断信心量表(5=最有信心)评估iRM血管性;以CEUS为参考标准。共41例患者、50个病灶符合纳入标准。

诊断标准与关键数值

  • 以CEUS为参考标准,单色SMI敏感度最高(63.3%),彩色SMI特异度最高(62.1%);彩色SMI和单色SMI诊断准确率最高(分别为0.678和0.680,均P < 0.001),高于CDI(0.568)和PDI(0.555)。

临床应用与阅片要点

  • 作者认为,与标准多普勒技术相比,SMI可能是检测不确定性肾脏肿块微血管的有用方法;未来研究应旨在比较SMI与CEUS的效能,并评估SMI鉴别iRM恶性的能力。

局限性

  • 原文结论称数据为初步数据(Preliminary data)。
  • 原文指出未来研究应比较SMI与CEUS的效能,并评估SMI鉴别iRM恶性的能力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Vascular assessment of indeterminate renal masses (iRMs) remains a crucial element of diagnostic imaging, as the presence of blood flow within renal lesions suggests malignancy. We compared the utility of Superb Microvascular Imaging (SMI; Canon Medical Systems, Tustin, CA), a novel Doppler technique, to standard color Doppler imaging (CDI) and power Doppler imaging (PDI) for the detection of vascularity within iRMs.

METHODS: Patients undergoing contrast-enhanced ultrasound (CEUS) evaluations for iRMs first underwent a renal ultrasound examination with the following modes: CDI, PDI, color Superb Microvascular Imaging (cSMI), and monochrome Superb Microvascular Imaging (mSMI), using an Aplio i800 scanner with an i8CX1 transducer (Canon Medical Systems). After image randomization, each mode was assessed for iRM vascularity by 4 blinded readers on a diagnostic confidence scale of 1 to 5 (5 = most confident). The results were compared to CEUS as the reference standard.

RESULTS: Forty-one patients with 50 lesions met inclusion criteria. Relative to the other 3 modalities, mSMI had the highest sensitivity (63.3%), whereas cSMI had the highest specificity (62.1%). Both cSMI and mSMI also had the highest diagnostic accuracy (0.678 and 0.680, respectively; both P < 0.001) compared to CDI (0.568) and PDI (0.555). Although the reader-reported confidence interval of mSMI (mean ± SD, 3.6 ± 1.1) was significantly lower than CDI (4.1 ± 1.0) and PDI (4.0 ± 1.0; P < 0.001), the confidence level of cSMI (4.1 ± 0.9) was not (P > 0.173).

CONCLUSIONS: Preliminary data suggest that SMI is a potentially useful modality in detecting microvasculature in iRMs compared to standard Doppler techniques. Future studies should aim to compare the efficacy of both SMI and CEUS and to assess the ability of SMI to characterize malignancy in iRMs.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Leong JY, Wessner CE, Kramer MR, et al. Superb Microvascular Imaging Improves Detection of Vascularity in Indeterminate Renal Masses. J Ultrasound Med. 2020. PMID: 32309889. doi:10.1002/jum.15299

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。