基于幅度与复合化学位移编码MRI估计的肝脏质子密度脂肪分数纵向变化的前瞻性比较
这项前瞻性双中心纵向研究的二次分析纳入54例重度肥胖且活检证实非酒精性脂肪性肝病并接受减重手术的成人,比较MRI-M与MRI-C估计的肝脏PDFF纵向变化。MRI-M在各时间点较MRI-C低估PDFF 0.5-0.7%(p<0.001),但两者估计的PDFF变化率高度一致(ICC 0.956-0.983)。
要点
- MRI-M较MRI-C在3T下低估肝脏PDFF约0.5-0.7%,但偏差一致。
- MRI-M与MRI-C估计的PDFF变化率高度一致(ICC 0.956-0.983)。
- 同一患者纵向随访应使用同一种MRI技术。
核心结论
- MRI-M较MRI-C横断面低估PDFF,但该偏差一致;MRI-M与MRI-C在纵向估计肝脏PDFF变化率上一致。
研究设计与样本
- 前瞻性双中心纵向研究的二次分析,纳入54例(44例女性;平均年龄52岁,范围27-70岁)重度肥胖、活检证实NAFLD且基线PDFF≥5%并接受减重手术的成人;采用3T化学位移编码MRI的幅度法与复合法在基线、极低热量饮食后2-4周及术后1、3、6个月估计PDFF。
诊断标准与关键数值
- 基线PDFF≥5%为纳入标准。
- MRI-M较MRI-C在各时间点低估PDFF 0.5-0.7%(p<0.001)。
- 访视1至3 PDFF变化率:ICC 0.983(95%CI 0.971-0.99),偏差-0.13%(p=0.22)。
- 访视3至5 PDFF变化率:ICC 0.956(95%CI 0.919-0.977%),偏差0.03%(p=0.36)。
临床应用与阅片要点
- 作者认为两种MRI技术(MRI-M或MRI-C)均可用于临床诊疗、单个中心或多中心试验中以PDFF变化为终点。
- 由于测量存在偏差,同一患者纵向随访应使用同一种技术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare longitudinal hepatic proton density fat fraction (PDFF) changes estimated by magnitude- vs. complex-based chemical-shift-encoded MRI during a weight loss surgery (WLS) program in severely obese adults with biopsy-proven nonalcoholic fatty liver disease (NAFLD).
METHODS: This was a secondary analysis of a prospective dual-center longitudinal study of 54 adults (44 women; mean age 52 years; range 27-70 years) with obesity, biopsy-proven NAFLD, and baseline PDFF ≥ 5%, enrolled in a WLS program. PDFF was estimated by confounder-corrected chemical-shift-encoded MRI using magnitude (MRI-M)- and complex (MRI-C)-based techniques at baseline (visit 1), after a 2- to 4-week very low-calorie diet (visit 2), and at 1, 3, and 6 months (visits 3 to 5) after surgery. At each visit, PDFF values estimated by MRI-M and MRI-C were compared by a paired t test. Rates of PDFF change estimated by MRI-M and MRI-C for visits 1 to 3, and for visits 3 to 5 were assessed by Bland-Altman analysis and intraclass correlation coefficients (ICCs).
RESULTS: MRI-M PDFF estimates were lower by 0.5-0.7% compared with those of MRI-C at all visits (p < 0.001). There was high agreement and no difference between PDFF change rates estimated by MRI-M vs. MRI-C for visits 1 to 3 (ICC 0.983, 95% CI 0.971, 0.99; bias = - 0.13%, p = 0.22), or visits 3 to 5 (ICC 0.956, 95% CI 0.919-0.977%; bias = 0.03%, p = 0.36).
CONCLUSION: Although MRI-M underestimates PDFF compared with MRI-C cross-sectionally, this bias is consistent and MRI-M and MRI-C agree in estimating the rate of hepatic PDFF change longitudinally.
KEY POINTS: • MRI-M demonstrates a significant but small and consistent bias (0.5-0.7%; p < 0.001) towards underestimation of PDFF compared with MRI-C at 3 T. • Rates of PDFF change estimated by MRI-M and MRI-C agree closely (ICC 0.96-0.98) in adults with severe obesity and biopsy- proven NAFLD enrolled in a weight loss surgery program. • Our findings support the use of either MRI technique (MRI-M or MRI-C) for clinical care or by individual sites or for multi-center trials that include PDFF change as an endpoint. However, since there is a bias in their measurements, the same technique should be used in any given patient for longitudinal follow-up.
引用
- Mamidipalli A, Fowler KJ, Hamilton G, et al. Prospective comparison of longitudinal change in hepatic proton density fat fraction (PDFF) estimated by magnitude-based MRI (MRI-M) and complex-based MRI (MRI-C). Eur Radiol. 2020. PMID: 32318847. doi:10.1007/s00330-020-06858-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。