新型深度学习图像重建用于腹部CT的图像质量评估:初步经验
本研究回顾性分析2019年4月至5月行肿瘤分期门静脉期腹部增强CT的成人病例,比较标准30%自适应统计迭代重建V(30% ASIR-V)与低、中、高强度深度学习图像重建(DLIR)的图像质量。高强度DLIR噪声降低47%,对比噪声比较30% ASIR-V提高92%–94%;所有DLIR级别的病灶诊断信心、清晰度和伪影评分均显著高于30% ASIR-V,但感知分辨率无显著差异。
要点
- 高强度DLIR噪声较30% ASIR-V降低47%,对比噪声比提高92%–94%。
- 所有DLIR级别的病灶诊断信心、清晰度和伪影评分均显著高于30% ASIR-V。
- DLIR与30% ASIR-V的感知分辨率无显著差异,DLIR强度增高伴随轻度模糊。
核心结论
- 与30% ASIR-V相比,DLIR改善了门静脉期腹部CT评估。
- DLIR强度应选择为在临床任务所需去噪程度与轻度模糊之间取得平衡,模糊随DLIR强度逐步增高而增加。
研究设计与样本
- 回顾性研究,纳入2019年4月至5月接受肿瘤分期门静脉期腹部增强CT的成人病例。
- 比较标准30%自适应统计迭代重建V(30% ASIR-V)与低、中、高强度DLIR重建。
- 进行衰减和噪声测量,并由两名对检查细节设盲的放射科医生对重建图像进行六类评分。
关键影像表现/征象
- DLIR的对比噪声比优于30% ASIR-V,高强度DLIR表现最佳。
- 高强度DLIR噪声较30% ASIR-V降低47%,对比噪声比较30% ASIR-V提高92%–94%。
- DLIR强度越高,整体图像质量及图像噪声与纹理评分显著越高。
诊断标准与关键数值
- 共识别193个病灶;所有DLIR级别的病灶诊断信心、清晰度和伪影评分均显著高于30% ASIR-V。
- 各重建方法间感知分辨率无显著差异。
临床应用与阅片要点
- DLIR可改善门静脉期腹部CT的图像质量和病灶诊断信心。
- 选择DLIR强度时需权衡去噪程度与随强度增高而加重的轻度模糊。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to perform quantitative and qualitative evaluation of a deep learning image reconstruction (DLIR) algorithm in contrast-enhanced oncologic CT of the abdomen. MATERIALS AND METHODS. Retrospective review (April-May 2019) of the cases of adults undergoing oncologic staging with portal venous phase abdominal CT was conducted for evaluation of standard 30% adaptive statistical iterative reconstruction V (30% ASIR-V) reconstruction compared with DLIR at low, medium, and high strengths. Attenuation and noise measurements were performed. Two radiologists, blinded to examination details, scored six categories while comparing reconstructions for overall image quality, lesion diagnostic confidence, artifacts, image noise and texture, lesion conspicuity, and resolution. RESULTS. DLIR had a better contrast-to-noise ratio than 30% ASIR-V did; high-strength DLIR performed the best. High-strength DLIR was associated with 47% reduction in noise, resulting in a 92-94% increase in contrast-to-noise ratio compared with that of 30% ASIR-V. For overall image quality and image noise and texture, DLIR scored significantly higher than 30% ASIR-V with significantly higher scores as DLIR strength increased. A total of 193 lesions were identified. The lesion diagnostic confidence, conspicuity, and artifact scores were significantly higher for all DLIR levels than for 30% ASIR-V. There was no significant difference in perceived resolution between the reconstruction methods. CONCLUSION. Compared with 30% ASIR-V, DLIR improved CT evaluation of the abdomen in the portal venous phase. DLIR strength should be chosen to balance the degree of desired denoising for a clinical task relative to mild blurring, which increases with progressively higher DLIR strengths.
引用
- Jensen CT, Liu X, Tamm EP, et al. Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience. AJR Am J Roentgenol. 2020. PMID: 32286872. doi:10.2214/AJR.19.22332
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。