点剪切波弹性成像能否作为受累的早期指标:囊性纤维化儿童的胰腺与肝脏评估

Can Point Shear Wave Elastography Be Used as an Early Indicator of Involvement?: Evaluation of the Pancreas and Liver in Children With Cystic Fibrosis.
PubMed 文献 · J Ultrasound Med · 2020-04-20

本研究用点剪切波弹性成像测量22例基因确诊囊性纤维化患儿与22例健康对照的胰腺和肝脏剪切波速度,患儿胰腺剪切波速度1.06±0.26 m/s高于对照0.85±0.23 m/s(P=0.01),肝脏剪切波速度1.46±0.24 m/s高于对照1.12±0.21 m/s(P=0.001),作者认为超声弹性成像可能有助于在明显临床、实验室和B超征象出现前评估胰腺和肝脏早期改变。

要点

  • 囊性纤维化患儿胰腺剪切波速度较健康对照升高(1.06±0.26 vs 0.85±0.23 m/s,P=0.01)。
  • 囊性纤维化患儿肝脏剪切波速度较健康对照升高(1.46±0.24 vs 1.12±0.21 m/s,P=0.001)。
  • 胰腺和肝脏剪切波速度在是否使用熊去氧胆酸、营养不良状态及F508缺失突变间无显著差异。

核心结论

  • 本研究表明囊性纤维化儿童胰腺剪切波速度升高,与文献报道相反。
  • 即使在无囊性纤维化相关肝病的情况下,肝脏剪切波速度也升高。
  • 超声弹性成像可能是评估囊性纤维化相关受累在明显临床、实验室和B超征象出现前早期改变的有用方法。

研究设计与样本

  • 研究纳入22例经基因确诊的囊性纤维化患儿和22例健康对照参与者。
  • 采用点剪切波弹性成像测量肝脏和胰腺的剪切波速度。

诊断标准与关键数值

  • 囊性纤维化患儿胰腺平均剪切波速度1.06±0.26 m/s,健康对照0.85±0.23 m/s(P=0.01)。
  • 囊性纤维化患儿肝脏平均剪切波速度1.46±0.24 m/s,健康对照1.12±0.21 m/s(P=0.001)。

临床应用与阅片要点

  • 作者认为超声弹性成像可能是评估囊性纤维化患儿胰腺和肝脏早期改变的有用方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to determine the effect of cystic fibrosis (CF) on pancreas and liver elasticity in young children using point shear wave elastography and to determine the relationship with clinical findings.

METHODS: Twenty-two patients with genetically proven CF, who were admitted to our pediatric gastroenterology clinic, and 22 healthy control participants were enrolled in the study. The shear wave velocity (SWV) of the liver and pancreas were measured with point shear wave elastography.

RESULTS: The 22 patients with CF included 45.5% girls with a mean age ± SD of 35 ± 35.8 months (range, 5-123 months). The 22 healthy control participants included 41.2% girls with a mean age of 58.9 ± 44.4 months (range, 2-159 months). The mean SWV of the pancreas in the patients with CF (1.06 ± 0.26 m/s) was significantly higher than that of the healthy control participants (0.85 ± 0.23 m/s; P = .01). The mean SWV of the liver in the patients with CF (1.46 ± 0.24 m/s) was significantly higher than that of the healthy control participants (1.12 ± 0.21 m/s; P = .001). The SWV of the pancreas and liver did not show any significant differences depending on ursodeoxycholic acid use, malnutrition status, and the presence of the F508 deletion mutation.

CONCLUSIONS: This study showed an increased SWV of the pancreas in children with CF, contrary to the literature. We also found an increased liver SWV even in the absence of CF-related liver disease. Ultrasound elastography may be a useful method of evaluating early changes in the pancreas and liver before the obvious clinical, laboratory, and B-mode ultrasound signs of CF-related involvement.

来源:J Ultrasound Med,查看原文。版权归原作者所有。