文献速递腹部技术与安全PETCT

进展期胃癌与原发性胃淋巴瘤的多种代谢参数及18F-FDG摄取异质性视觉评估的PET/CT研究

Multiple metabolic parameters and visual assessment of 18F-FDG uptake heterogeneity of PET/CT in advanced gastric cancer and primary gastric lymphoma.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

回顾性纳入70例进展期胃癌和26例原发性胃淋巴瘤患者,分析PET/CT转移灶分布、代谢参数(SUVmax、SUVmax/THKmax、MTV、TLG)及18F-FDG摄取异质性视觉评分与SUVmax-d。原发性胃淋巴瘤的SUVmax、SUVmax/THKmax、TLG更高,SUVmax-d显著高于进展期胃癌,SUVmax的AUC和准确率(77.2%)最高。

要点

  • 进展期胃癌常见转移部位为肝、骨、腹膜及近端淋巴结;原发性胃淋巴瘤腹膜转移较少,淋巴结转移可呈「跳跃性转移」。
  • 原发性胃淋巴瘤的SUVmax、SUVmax/THKmax及TLG高于进展期胃癌,弥漫大B细胞淋巴瘤(DLBCL)尤为明显。
  • 视觉评估18F-FDG摄取异质性时,原发性胃淋巴瘤的SUVmax-d测量值显著高于进展期胃癌,SUVmax诊断综合效率最高(准确率77.2%)。

关键影像表现/征象

  • 进展期胃癌最常见转移部位为肝、骨、腹膜和近端淋巴结;原发性胃淋巴瘤腹膜转移较少,淋巴结转移可表现为「跳跃性转移」。
  • 原发性胃淋巴瘤的SUVmax、SUVmax/THKmax和TLG高于进展期胃癌,弥漫大B细胞淋巴瘤(DLBCL)中尤为明显。
  • 视觉评估18F-FDG摄取异质性时,原发性胃淋巴瘤的SUVmax-d测量值显著高于进展期胃癌。

诊断标准与关键数值

  • 受试者工作特征曲线分析显示,SUVmax的曲线下面积最大、准确率最高(77.2%),综合诊断效率最高。
  • 视觉评分法及测量SUVmax差值(SUVmax-d)用于评估18F-FDG摄取异质性。
  • 代谢参数包括SUVmax、SUVmax/THKmax、代谢性肿瘤体积(MTV)和总病灶糖酵解(TLG)。

临床应用与阅片要点

  • 阅片时可关注转移灶分布模式:进展期胃癌常见肝、骨、腹膜及近端淋巴结转移,原发性胃淋巴瘤腹膜转移较少且淋巴结转移可呈「跳跃性转移」。
  • 测量SUVmax、SUVmax/THKmax及TLG有助于提示原发性胃淋巴瘤(尤其DLBCL),其值高于进展期胃癌。
  • 视觉评估18F-FDG摄取异质性并测量SUVmax-d,可作为鉴别进展期胃癌与原发性胃淋巴瘤的辅助方法,作者认为其意义需未来研究阐明。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Advanced gastric cancer (AGC) and primary gastric lymphoma (PGL) are the two most common malignant tumors of the stomach. Conventional imaging examinations have difficulty distinguishing the two. This study explored the values of multiple parameters and visual assessment of 18F-fluorodeoxyglucose(18F-FDG) uptake heterogeneity of positron emission tomography/computed tomography(PET/CT) for differentiating between AGC and PGL.

METHODS: This retrospective study included 70 AGC and 26 PGL patients, all of whom had undergone 18F-FDG PET/CT before treatment. We analyzed the differences between AGC and PGL in the distribution of metastatic lesions and multiple metabolic parameters, including the maximum standardized uptake value (SUVmax), SUVmax/maximal thickness(THKmax), metabolic tumor volume and total lesion glycolysis (TLG). In addition, 18F-FDG uptake heterogeneity was visually assessed using a visual scoring method and a method of measuring SUVmax differences (SUVmax-d).

RESULTS: The most common metastasis of AGC patients were liver, bone, peritoneal and proximal lymph nodes; PGL patients had fewer peritoneal metastases and lymph node metastasis could appeared to be "skip metastasis." The metabolic parameters-SUVmax, SUVmax/THKmax and TLG-were higher in patients who had PGL, especially in diffuse large B-cell lymphoma (DLBCL). In the visual assessment of 18F-FDG uptake heterogeneity, the measurements of SUVmax-d in PGL were significantly higher than in AGC. Receiver operating characteristics curve analysis suggested that SUVmax has the highest comprehensive diagnostic efficiency due to having the highest value of area under the curve and the highest accuracy (77.2%).

CONCLUSION: 18F-FDG PET/CT had a high diagnostic efficiency for discrimination of AGC and PGL, especially between DLBCL and other pathological subtypes. Visual assessment used to evaluate 18F-FDG uptake heterogeneity could help to distinguish the two types of tumors. In addition, our innovative method of measuring the heterogeneity of 18F-FDG uptake-namely, SUVmax-d-could contribute to identification of the two tumor types and should have its significance clarified by future studies.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ren Y, Liu J, Wang L, et al. Multiple metabolic parameters and visual assessment of 18F-FDG uptake heterogeneity of PET/CT in advanced gastric cancer and primary gastric lymphoma. Abdom Radiol (NY). 2020. PMID: 32274551. doi:10.1007/s00261-020-02503-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。