利用计算模型从单张数字X线摄影确定患者腹部厚度:一项概念验证研究的临床结果
该研究创建计算模型,通过腹部前后位X线图像、曝光参数、X线设备与探测器特性及蒙特卡罗模拟结果估算患者腹部厚度,在20例成人患者中与直接测量对比,模型估计值平均在实测厚度±5.8%以内。结论认为在患者体型处于建模所用范围内时,该模型可准确估算腹部前后位X线检查患者的厚度,可用于辅助儿科X线检查的患者剂量审计。
要点
- 计算模型利用单张腹部前后位数字X线图像及曝光参数估算患者腹部厚度。
- 20例成人患者中,模型估计厚度与直接测量值平均偏差在±5.8%以内。
- 模型适用于患者体型处于建模所用患者范围内的情形。
核心结论
- 计算模型可准确估算接受腹部前后位X线检查患者的厚度,前提是患者体型处于建模所用患者范围内。
研究设计与样本
- 概念验证研究,纳入20例接受腹部前后位X线检查的成人患者,将模型估计厚度与检查时直接测量值进行比较。
诊断标准与关键数值
- 模型估算患者厚度与实测厚度相比,平均在±5.8%以内。
临床应用与阅片要点
- 该模型的应用目标为辅助儿科X线检查的患者剂量审计。
局限性
- 模型仅适用于患者体型处于建模所用患者范围内的情形。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: A computational model has been created to estimate the abdominal thickness of a patient following an X-ray examination; its intended application is assisting with patient dose audit of paediatric X-ray examinations. This work evaluates the accuracy of the computational model in a clinical setting for adult patients undergoing anteroposterior (AP) abdomen X-ray examinations.
METHODS: The model estimates patient thickness using the radiographic image, the exposure factors with which the image was acquired, a priori knowledge of the characteristics of the X-ray unit and detector and the results of extensive Monte Carlo simulation of patient examinations. For 20 patients undergoing AP abdominal X-ray examinations, the model was used to estimate the patient thickness; these estimates were compared against a direct measurement made at the time of the examination.
RESULTS: Estimates of patient thickness made using the model were on average within ±5.8% of the measured thickness.
CONCLUSION: The model can be used to accurately estimate the thickness of a patient undergoing an AP abdominal X-ray examination where the patient's size falls within the range of the size of patients used to create the computational model.
ADVANCES IN KNOWLEDGE: This work demonstrates that it is possible to accurately estimate the AP abdominal thickness of an adult patient using the digital X-ray image and a computational model.
引用
- Worrall M, Vinnicombe S, Sutton D, et al. Determining patient abdomen thickness from a single digital radiograph with a computational model: clinical results from a proof of concept study. Br J Radiol. 2020. PMID: 32267728. doi:10.1259/bjr.20200010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。