慢性主动脉夹层中预测肾损伤的CT血管成像表现
回顾性分析87例慢性残余主动脉夹层患者,比较假腔供血肾与真腔供血肾的容积和有效肾血浆流量。假腔供血肾随访时有效肾血浆流量和容积均低于真腔供血肾,尤其在肾动脉受累、假腔面积小及缺乏近端主入口时更明显。
要点
- 假腔供血肾随访时有效肾血浆流量和容积均低于真腔供血肾。
- 近端主入口存在和假腔面积大是假腔供血肾低灌注的保护因素。
- 肾动脉受累时假腔供血肾有效肾血浆流量和容积下降更显著。
核心结论
- 假腔供血肾随访时容积减小、有效肾血浆流量降低,尤其在肾动脉受累、肾水平假腔面积小及缺乏近端主入口时。
- 作者认为需进一步研究以明确假腔供血肾低灌注的临床意义。
研究设计与样本
- 回顾性分析前瞻性收集的2005至2013年87例慢性残余主动脉夹层患者数据,每例一侧肾由真腔供血、另一侧由假腔供血。
- 采用CT血管成像观察影像特征,并测量有效肾血浆流量和肾容积。
关键影像表现/征象
- 假腔供血肾随访时平均有效肾血浆流量为117.5 ± 42.6 mL/min,真腔供血肾为146.6 ± 41.0 mL/min(p = 0.004)。
- 假腔供血肾平均容积为131.1 ± 37.1 cm3,真腔供血肾为146.5 ± 33.3 cm3(p = 0.004)。
- 肾动脉受累患者中,假腔供血肾平均有效肾血浆流量为88.5 ± 26.8 mL/min,真腔供血肾为149.6 ± 43.5 mL/min(p = 0.004)。
- 肾动脉受累患者中,假腔供血肾平均容积为120.4 ± 30.4 cm3,真腔供血肾为152.3 ± 24.6 cm3(p = 0.001)。
诊断标准与关键数值
- 多因素分析显示近端主入口存在(OR 0.306;95% CI 0.103-0.910;p = 0.033)和假腔面积大(OR 0.104;95% CI 0.012-0.880;p = 0.038)是假腔供血肾低灌注的保护因素。
局限性
- 原文结论指出需进一步研究以明确假腔供血肾低灌注的临床意义。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to compare the volume alteration and effective renal plasma flow of kidneys supplied by false lumens (FLs) with those of kidneys supplied by true lumens (TLs), to show the discrepancy in perfusion between the two lumens. We sought to corroborate malperfusion of FL-supplied kidneys with imaging characteristics observed on CT angiography. MATERIALS AND METHODS. A retrospective analysis was conducted using prospectively collected data for 87 patients with a diagnosis of residual chronic aortic dissection between 2005 and 2013 who had one kidney perfused by a TL and the other kidney perfused by a FL. RESULTS. Overall, at follow-up, FL-supplied kidneys had a mean (± SD) effective renal plasma flow (117.5 ± 42.6 vs 146.6 ± 41.0 mL/min; p = 0.004) and volume (131.1 ± 37.1 vs 146.5 ± 33.3 cm3; p = 0.004) that were lower than those of TL-supplied kidneys. Multivariate analysis revealed the presence of a proximal major inlet (odds ratio, 0.306; 95% CI, 0.103-0.910; p = 0.033) and large FL area (odds ratio, 0.104; CI, 0.012-0.880; p = 0.038) as factors protecting against malperfusion of FL-supplied kidneys. In patients with dissected renal arteries, the FL-supplied kidney had low effective renal plasma flow (mean, 88.5 ± 26.8 vs 149.6 ± 43.5 mL/min; p = 0.004) and diminished volume (mean, 120.4 ± 30.4 vs 152.3 ± 24.6 cm3; p = 0.001). CONCLUSION. In the present study, kidneys perfused by FLs showed decreased volume and reduced effective renal plasma flow during follow-up, particularly those kidneys with dissected renal arteries, a small FL area at the renal level, and lack of a proximal major inlet. Further studies are warranted to identify the clinical relevance of malperfusion in FL-supplied kidneys.
引用
- Kuo TT, Chen PL, Huang CY, et al. CT Angiography Findings Predictive of Kidney Injury in Chronic Aortic Dissection. AJR Am J Roentgenol. 2020. PMID: 32286876. doi:10.2214/AJR.19.21877
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。