定量血流分数与灌注成像诊断心肌缺血的性能比较
本研究在208例(624支血管)患者中头对头比较定量血流分数(QFR)与SPECT和PET心肌灌注成像对血流储备分数(FFR)定义冠心病的诊断性能。QFR计算在286支(52%)血管中成功,其敏感度70%与PET的75%相似而优于SPECT的29%,特异度93%高于PET的79%而与SPECT的96%无差异,准确度88%优于SPECT的82%和PET的78%,曲线下面积0.94高于SPECT的0.63和PET的0.82。
要点
- QFR计算仅基于侵入性冠状动脉造影电影图像,在552支FFR检查血管中286支(52%)计算成功。
- QFR诊断FFR定义冠心病的敏感度70%与PET的75%相似,高于SPECT的29%。
- QFR特异度93%高于PET的79%,与SPECT的96%无显著差异。
核心结论
- 在头对头比较研究中,QFR对检测FFR定义显著冠心病的诊断价值高于SPECT或PET灌注成像。
研究设计与样本
- 头对头比较研究,共208例患者(624支血管),在侵入性冠状动脉造影和FFR测量前接受锝-99m替曲膦SPECT和[15O]H2O PET心肌灌注成像。
诊断标准与关键数值
- QFR与侵入性FFR总体相关性良好(R=0.79,p<0.001),在直径狭窄30%至90%的中间病变亚组中R=0.76(p<0.001)。
- 按血管分析,QFR敏感度70%高于SPECT的29%(p<0.001),与PET的75%相似(p=1.000)。
- QFR特异度93%高于PET的79%(p<0.001),与SPECT的96%无差异(p=1.000)。
- QFR准确度88%高于SPECT的82%(p=0.010)和PET的78%(p=0.004)。
- QFR的ROC曲线下面积在总体样本为0.94、中间病变血管为0.90,分别高于SPECT的0.63和0.61(两者p<0.001)及PET的0.82(p<0.001)和0.77(p=0.002)。
临床应用与阅片要点
- QFR可基于未采用专用QFR采集方案的侵入性冠状动脉造影图像计算,本研究中552支FFR检查血管仅286支(52%)计算成功。
- QFR对FFR定义冠心病的敏感度与PET相似而高于SPECT,特异度高于PET而与SPECT无差异,准确度和曲线下面积均高于两种灌注成像。
局限性
- QFR计算在552支FFR检查血管中仅286支(52%)成功,原文未报告失败原因。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study compared the performance of the quantitative flow ratio (QFR) with single-photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) for the diagnosis of fractional flow reserve (FFR)-defined coronary artery disease (CAD).
BACKGROUND: QFR estimates FFR solely based on cine contrast images acquired during invasive coronary angiography (ICA). Head-to-head studies comparing QFR with noninvasive MPI are lacking.
METHODS: A total of 208 (624 vessels) patients underwent technetium-99m tetrofosmin SPECT and [15O]H2O PET imaging before ICA in conjunction with FFR measurements. ICA was obtained without using a dedicated QFR acquisition protocol, and QFR computation was attempted in all vessels interrogated by FFR (552 vessels).
RESULTS: QFR computation succeeded in 286 (52%) vessels. QFR correlated well with invasive FFR overall (R = 0.79; p < 0.001) and in the subset of vessels with an intermediate (30% to 90%) diameter stenosis (R = 0.76; p < 0.001). Overall, per-vessel analysis demonstrated QFR to exhibit a superior sensitivity (70%) in comparison with SPECT (29%; p < 0.001), whereas it was similar to PET (75%; p = 1.000). Specificity of QFR (93%) was higher than PET (79%; p < 0.001) and not different from SPECT (96%; p = 1.000). As such, the accuracy of QFR (88%) was superior to both SPECT (82%; p = 0.010) and PET (78%; p = 0.004). Lastly, the area under the receiver operating characteristics curve of QFR, in the overall sample (0.94) and among vessels with an intermediate lesion (0.90) was higher than SPECT (0.63 and 0.61; p < 0.001 for both) and PET (0.82; p < 0.001 and 0.77; p = 0.002), respectively.
CONCLUSIONS: In this head-to-head comparative study, QFR exhibited a higher diagnostic value for detecting FFR-defined significant CAD compared with perfusion imaging by SPECT or PET.
引用
- van Diemen PA, Driessen RS, Kooistra RA, et al. Comparison Between the Performance of Quantitative Flow Ratio and Perfusion Imaging for Diagnosing Myocardial Ischemia. JACC Cardiovasc Imaging. 2020. PMID: 32305469. doi:10.1016/j.jcmg.2020.02.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。