文献速递胸部MR

自由呼吸、运动稳健的动态对比增强MRI协议评估胸膜肿瘤的临床实施

Clinical Implementation of a Free-Breathing, Motion-Robust Dynamic Contrast-Enhanced MRI Protocol to Evaluate Pleural Tumors.
PubMed 文献 · AJR Am J Roentgenol · 2020-04-29

本研究开发了一种对运动不敏感的临床动态对比增强MRI协议,用于评估临床试验中胸膜肿瘤的治疗反应。32例胸膜病变患者接受三种梯度回波DCE-MRI序列变体(FLASH、TWIST、径向采集)及标准影像序列,径向序列最运动稳健(头足方向平均位移0.4±1.2 mm),FLASH居中(4.6±2.0 mm),TWIST最敏感(6.4±3.4 mm)。模拟显示运动可导致动力学参数估计明显不准确及嵌套模型分析中动力学模型收敛不当。

要点

  • 径向采集序列运动最稳健,头足方向平均位移0.4±1.2 mm,为亚体素水平。
  • TWIST序列对运动最敏感,平均位移6.4±3.4 mm,FLASH居中为4.6±2.0 mm。
  • 运动可导致胸膜病变动力学参数估计明显不准确及模型收敛不当。

关键影像表现/征象

  • 径向序列运动最稳健,头足方向平均位移0.4±1.2 mm(标准差),为亚体素水平。
  • FLASH序列显示中等位移4.6±2.0 mm
  • TWIST序列对运动最敏感,位移6.4±3.4 mm
  • 径向序列重建图像的信噪比和对比噪声比在改进密度补偿算法后与FLASH和TWIST序列相当或更优

临床应用与阅片要点

  • 径向k空间轨迹序列可提供运动不敏感的 pharmacokinetic 参数,已纳入胸膜肿瘤DCE-MRI协议。
  • 模拟显示胸膜病变扫描中的运动可导致动力学参数估计明显不准确及嵌套模型分析中动力学模型收敛不当。

局限性

  • 原文指出需要在临床试验中验证该协议评估治疗反应的有效性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to develop a motion insensitive clinical dynamic contrast-enhanced MRI (DCE-MRI) protocol to assess the response of pleural tumors in clinical trials. MATERIALS AND METHODS. Thirty-two patients with pleura-based lesions were administered contrast material and imaged with gradient-recalled echo DCE-MRI sequence variants: either a traditional cartesian k-space acquisition (FLASH), a time-resolved imaging with stochastic trajectories acquisition (TWIST), or a radial stack-of-stars acquisition (radial) sequence in addition to other standard-of-care imaging sequences. Each image acquisition's sensitivity to motion was evaluated by comparing the motion of the thoracic border in 3D throughout the acquisition. One-way ANOVA was used to compare the image quality between different acquisitions. The 95% CIs were calculated for mean thoracic border displacement. The effects of motion on kinetic parameter estimation were explored with simulations according to clinically acquired data. RESULTS. Radial was the most motion-robust sequence with subvoxel mean displacement in the superior-inferior direction (0.4 ± 1.2 [SD] mm). FLASH showed intermediate displacement (4.6 ± 2.0 mm), whereas TWIST was most sensitive to motion (6.4 ± 3.4 mm). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images acquired with the radial sequence were on par or better than the FLASH and TWIST sequences when reconstructed with an improved density compensation algorithm. Simulations showed that motion on scans showing pleural-based lesions can lead to markedly inaccurate kinetic parameter estimation and inappropriate kinetic model convergence within a nested model analysis. CONCLUSION. A practical radial k-space trajectory sequence that provides motion-insensitive pharmacokinetic parameters was incorporated as part of the DCE-MRI protocol of pleural tumors. Validation and usefulness in clinical trials assessing response to therapy is needed.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Ng TSC, Seethamraju RT, Bueno R, et al. Clinical Implementation of a Free-Breathing, Motion-Robust Dynamic Contrast-Enhanced MRI Protocol to Evaluate Pleural Tumors. AJR Am J Roentgenol. 2020. PMID: 32348181. doi:10.2214/AJR.19.21612

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。