基于第三代双源CT的100 kVp锡滤线谱成形低剂量长螺距胸部CT协议用于2019冠状病毒病(COVID-19)患者的可行性研究
该可行性研究纳入COVID-19且拭子检测阳性的患者,比较第三代双源CT上双能量采集(HD-DECT,90/150Sn kVp)与100Sn kVp快速低剂量长螺距双源扫描(LDCT)的辐射剂量、采集时间及图像质量。LDCT中位有效剂量0.28 mSv,低于HD-DECT的3.28 mSv(p=0.016);LDCT中位采集时间0.62 s,短于HD-DECT的2.02 s(p=0.016);除肺实质外,多个胸部结构的SNR和CNR在两种方案间存在显著差异,LDCT运动伪影显著减少(p=0.031),诊断可靠性相当。作者结论认为该超低剂量双源快速CT协议可为COVID-19提供高度诊断价值的图像,并可能降低剂量和运动伪影。
要点
- LDCT中位有效剂量0.28 mSv,低于HD-DECT的3.28 mSv(p=0.016)。
- LDCT中位采集时间0.62 s,短于HD-DECT的2.02 s(p=0.016)。
- LDCT运动伪影较HD-DECT显著减少(p=0.031),诊断可靠性相当。
关键影像表现/征象
- LDCT运动伪影较HD-DECT显著减少(p=0.031)。
- 除肺实质外,HD-DECT与LDCT在多个胸部结构的SNR和CNR存在显著差异。
- HD-DECT与LDCT的诊断可靠性相当。
临床应用与阅片要点
- 作者结论认为该超低剂量双源快速CT协议可为COVID-19提供高度诊断价值的图像,并可能降低剂量和运动伪影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To subjectively and objectively evaluate the feasibility and diagnostic reliability of a low-dose, long-pitch dual-source chest CT protocol on third-generation dual-source CT (DSCT) with spectral shaping at 100Sn kVp for COVID-19 patients.
MATERIALS AND METHODS: Patients with COVID-19 and positive swab-test undergoing to a chest CT on third-generation DSCT were included. The imaging protocol included a dual-energy acquisition (HD-DECT, 90/150Sn kVp) and fast, low-dose, long-pitch CT, dual-source scan at 100Sn kVp (LDCT). Subjective (Likert Scales) and objective (signal-to-noise and contrast-to-noise ratios, SNR and CNR) analyses were performed; radiation dose and acquisition times were recorded. Nonparametric tests were used.
RESULTS: The median radiation dose was lower for LDCT than HD-DECT (Effective dose, ED: 0.28 mSv vs. 3.28 mSv, p = 0.016). LDCT had median acquisition time of 0.62 s (vs 2.02 s, p = 0.016). SNR and CNR were significantly different in several thoracic structures between HD-DECT and LDCT, with exception of lung parenchyma. Qualitative analysis demonstrated significant reduction in motion artifacts (p = 0.031) with comparable diagnostic reliability between HD-DECT and LDCT.
CONCLUSIONS: Ultra-low-dose, dual-source, fast CT protocol provides highly diagnostic images for COVID-19 with potential for reduction in dose and motion artifacts.
引用
- Agostini A, Floridi C, Borgheresi A, et al. Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: a feasibility study. Radiol Med. 2020. PMID: 32239472. doi:10.1007/s11547-020-01179-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。