文献速递胸部MR

回顾性软门控呼吸运动分辨四维零回波时间(4D ZTE)肺MRI:可行性与图像质量 compared with 3D ZTE 的比较研究

Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE.
PubMed 文献 · Eur Radiol · 2020-04-24

本研究纳入21例患者,分别采用前瞻性软门控3D ZTE与回顾性软门控呼吸运动分辨4D ZTE行肺部扫描。4D ZTE在肺实质与胸部结构的SNR、外周支气管与外周肺血管及结节或肿块的CNR均显著高于3D ZTE(均p<0.001),两名独立放射科医师的主观图像质量评价也显示4D ZTE在肺内结构、噪声与伪影及整体可接受性上更优(均p<0.001)。正常与低肺功能组间图像质量在3D ZTE中差异显著(均p<0.05),在4D ZTE中无显著差异。

要点

  • 4D ZTE肺实质与胸部结构SNR、外周支气管与外周肺血管及结节或肿块CNR均显著高于3D ZTE(均p<0.001)。
  • 两名独立放射科医师主观评价显示4D ZTE肺内结构、噪声与伪影及整体可接受性均优于3D ZTE(均p<0.001)。
  • 正常与低肺功能组图像质量在3D ZTE中差异显著(均p<0.05),在4D ZTE中无显著差异。

核心结论

  • 呼吸运动分辨4D ZTE肺部成像可作为常规胸部MRI的一部分实施。
  • 4D ZTE提供运动稳健的肺实质图像,其SNR与CNR优于3D ZTE,且不受患者肺功能影响。

研究设计与样本

  • 经本机构审查委员会批准的前瞻性可行性研究,共纳入21例患者。
  • 患者分别接受前瞻性软门控3D ZTE与回顾性软门控4D ZTE序列肺部扫描。
  • 比较3D ZTE与4D ZTE在呼气末期的客观与主观图像质量,并比较不同肺功能两组间呼气末期图像质量。

关键影像表现/征象

  • 4D ZTE肺实质与胸部结构的SNR显著高于3D ZTE(均p<0.001)。
  • 4D ZTE外周支气管、外周肺血管及结节或肿块的CNR显著高于3D ZTE(均p<0.001)。
  • 主观评价中4D ZTE的肺内结构、噪声与伪影及整体可接受性均优于3D ZTE(均p<0.001)。
  • 正常与低肺功能组的图像质量在3D ZTE中差异显著(均p<0.05),在4D ZTE中无显著差异。

诊断标准与关键数值

  • 以客观SNR、CNR及两名独立放射科医师主观评分(肺内结构、噪声与伪影、整体可接受性)作为图像质量评价指标。

临床应用与阅片要点

  • 4D ZTE可作为常规胸部MRI的组成部分用于肺实质成像。
  • 4D ZTE对患者肺功能与呼吸配合的依赖较小,图像质量受肺功能影响小于3D ZTE。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the feasibility and image quality of respiratory motion-resolved 4D zero echo time (ZTE) lung MRI compared with that of 3D ZTE.

METHODS: Our institutional review board approved this study. Twenty-one patients underwent lung scans using 3D ZTE and 4D ZTE sequences via prospective and retrospective soft gating techniques, respectively. Image qualities of 3D ZTE and 4D ZTE at end-expiration were compared through objective and subjective assessments. The quality of end-expiratory images of 3D ZTE and 4D ZTE of the two groups with different lung functions was also compared.

RESULTS: Images were successfully acquired in all patients without any adverse events. Signal-to-noise ratios (SNRs) of lung parenchyma and thoracic structures were significantly (all p < 0.001) higher in 4D ZTE. Contrast-to-noise ratios (CNRs) of peripheral bronchi, peripheral pulmonary vessels, and nodules or masses were significantly (all p < 0.001) higher in 4D ZTE. The subjective image quality assessed by two independent radiologists showed that intrapulmonary structures, noise and artifacts, and overall acceptability were superior in 4D ZTE (all p < 0.001). Image qualities of groups with normal and low lung functions differed significantly (all p < 0.05) in 3D ZTE, but not in 4D ZTE. The mean acquisition time was 136 s (127-143 s) in 3D ZTE and 325 s (308-352 s) in 4D ZTE.

CONCLUSIONS: Respiratory motion-resolved 4D ZTE lung imaging was feasible as part of routine chest MRI. The 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR than the 3D ZTE, regardless of patients' lung function.

KEY POINTS: • ZTE MRI captures rapidly decaying transverse magnetization in the lung parenchyma. • 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR compared with 3D ZTE. • Compared with 3D ZTE, the image quality of 4D ZTE lung MRI was affected less by patients' lung function and respiratory performance.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bae K, Jeon KN, Hwang MJ, et al. Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE. Eur Radiol. 2020. PMID: 32333146. doi:10.1007/s00330-020-06890-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。