计算机断层扫描特征可鉴别4型先天性肺气道畸形与其他囊性先天性肺气道畸形

Computed tomography features can distinguish type 4 congenital pulmonary airway malformation from other cystic congenital pulmonary airway malformations.
PubMed 文献 · Eur J Radiol · 2020-03-19

本研究回顾性分析2008至2018年145例经病理证实的囊性先天性肺气道畸形(CPAM)患儿的临床与CT资料,其中1型54例、2型72例、4型19例。结果显示囊腔直径>7.9 cm、纵隔移位和气胸是4型CPAM最重要的CT特征,CT特征可鉴别4型CPAM与其他囊性CPAM。

要点

  • 囊腔直径>7.9 cm、纵隔移位和气胸是4型CPAM最重要的CT特征。
  • 囊腔直径<2.8 cm更可能为2型,2.8-7.9 cm更可能为1型。
  • 4型CPAM中男性患者显著更多,2型更常合并其他畸形及产前诊断。

关键影像表现/征象

  • 囊性CPAM中位直径为2.8 cm,1型、2型、4型分别为4.6 cm、1.5 cm、8.1 cm。
  • 纵隔移位和气胸的发生频率在4型中更高,差异有统计学意义。
  • 2型肺炎发生率高于4型和1型。
  • 4型CPAM中男性患者显著更多。
  • 2型合并其他畸形和产前诊断的频率高于1型和4型。

诊断标准与关键数值

  • 回归分析显示囊腔直径>7.9 cm更可能为4型。
  • 囊腔直径<2.8 cm更可能为2型。
  • 囊腔直径2.8-7.9 cm更可能为1型。
  • 囊腔越小越可能为2型,越大越可能为4型。

临床应用与阅片要点

  • 阅片时测量囊腔最大直径并结合纵隔移位、气胸等征象,有助于提示4型CPAM。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to identify clinical and computed tomography (CT) features that distinguish among cystic congenital pulmonary airway malformations (CPAMs) and offer new management strategies.

METHODS: We retrieved data on 145 children (85 male, 60 female; median age, 14 months) with pathologically confirmed cystic CPAMs from 2008 to 2018 and retrospectively analyzed the clinical and CT characteristics.

RESULTS: Of the 145 patients, 54 had type 1, 72 had type 2, and 19 had type 4 cystic CPAMs. Significantly more male patients had type 4 CPAMs. Type 2 CPAMs had a higher frequency of combined malformations and prenatal diagnosis than types 1 and 4. The median diameter of cystic CPAMs was 2.8 cm; that of type 1, 2, and 4 was 4.6, 1.5, and 8.1 cm, respectively. Regression analysis showed that a cyst of >7.9 cm in diameter was likely to be type 4, that of <2.8 cm was likely to be type 2, and that of 2.8-7.9 cm was likely to be type 1. Smaller cysts were more likely to be type 2 and larger cysts were more likely to be type 4. The incidence of pneumonia was higher in type 2 than in types 4 and 1. The frequency of mediastinal shift and pneumothorax was statistically significant, and both were more common in type 4.

CONCLUSION: A cyst of >7.9 cm in diameter, mediastinal shift, and pneumothorax were the most important characteristics of type 4 CPAMs. CT features can distinguish type 4 CPAM from other cystic CPAMs.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wu H, Tian J, Li H, et al. Computed tomography features can distinguish type 4 congenital pulmonary airway malformation from other cystic congenital pulmonary airway malformations. Eur J Radiol. 2020. PMID: 32224324. doi:10.1016/j.ejrad.2020.108964

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。