预测表现为磨玻璃影为主结节的肺腺癌病理浸润性:基于双能CT生成的联合预测模型
回顾性纳入2017年12月至2019年7月完全切除且行双能CT检查的143例磨玻璃影为主肺腺癌,比较浸润性腺癌与前浸润/微浸润腺癌的定性和定量指标,建立联合预测模型。边缘、最大直径和CT60 keV值为独立预测因子,联合模型AUC为0.896(敏感度90.2%,特异度70.7%,准确率84.6%),显著高于任意两两组合。
要点
- 边缘、最大直径和CT60 keV值是浸润性腺癌的独立预测因子。
- 联合模型AUC 0.896,敏感度90.2%,特异度70.7%,准确率84.6%。
- 联合模型诊断效能显著高于任意两两组合(均P<0.05)。
关键影像表现/征象
- 浸润性腺癌组边缘、内部扩张/扭曲/截断支气管、内部增厚/僵硬/扭曲血管、胸膜凹陷和血管集束的比例均高于前浸润-微浸润腺癌组。
- 浸润性腺癌组最大直径(Dmax)、实性成分直径(Dsolid)和40 keV-190 keV增强单能CT值(CT40 keV-190 keV)均高于前浸润-微浸润腺癌组(p范围:0.001-0.019)。
诊断标准与关键数值
- 逻辑回归显示边缘、最大直径(Dmax)和CT60 keV值是浸润性腺癌组的独立预测因子。
- 边缘、Dmax和CT60 keV值联合的AUC为0.896(敏感度90.2%,特异度70.7%,准确率84.6%),显著高于其中任意两两组合(均p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate qualitative and quantitative indicators generated from Dual-energy computed tomography (DECT) for preoperatively differentiating between invasive adenocarcinoma (IAC) and preinvasive or minimally invasive adenocarcinoma (MIA) lesions manifesting as ground-glass opacity-predominant (GGO-predominant) nodules.
MATERIALS AND METHODS: We retrospectively enrolled 143 cases of completely resected GGO-predominant lung adenocarcinoma with DECT examinations between December 2017 and July 2019. Qualitative and quantitative parameters of GGO-predominant nodules were compared after grouping nodules into IAC and preinvasive-MIA groups. A multivariate logistic regression models were used for analyzing these parameters. The diagnostic performance of different parameters was compared by receiver operating characteristic (ROC) curves and Z tests.
RESULTS: This study included 137 patients (58 years ± 11; male: female = 52:91) with 143 GGO-predominant nodules. The proportion of margins, internal dilated/distorted/cut-off bronchi, internal thickened/stiff/distorted vasculature, pleural indentation, and vascular convergence were higher in the IAC group than in the preinvasive-MIA group, as were the maximum diameter (Dmax), the diameter of the solid component (Dsolid) and the enhanced monochromatic CT value at 40 keV-190 keV (CT40 keV-190 keV) (p range: 0.001-0.019). Logistic regression analyses revealed that margin, Dmax, and CT60 keV values were independent predictors of the IAC group. The area under the curve (AUC) for the combination of margin, Dmax, and CT60 keV was 0.896 (90.2% sensitivity, 70.7% specificity, 84.6% accuracy), which was significantly higher than that for each two of them (all p < 0.05).
CONCLUSION: The combined prediction model generated from DECT allows for effective preoperative differentiation between IAC and preinvasive-MIA in GGO-predominant lung adenocarcinomas.
引用
- Wang S, Liu G, Fu Z, et al. Predicting Pathological Invasiveness of Lung Adenocarcinoma Manifesting as GGO-Predominant Nodules: A Combined Prediction Model Generated From DECT. Acad Radiol. 2020. PMID: 32303445. doi:10.1016/j.acra.2020.03.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。