文献速递胸部CT

基于CT定量影像组学方法鉴别肺腺癌主要亚型

Differentiation of predominant subtypes of lung adenocarcinoma using a quantitative radiomics approach on CT.
PubMed 文献 · Eur Radiol · 2020-04-16

本研究纳入993例浸润性肺腺癌患者,按主要组织学亚型预后分为三组(0组:贴壁型;1组:腺泡型/乳头型;2组:实体型/微乳头型),从增强CT提取718个影像组学特征构建模型。模型在开发集和测试集的AUC分别为0.892和0.895,测试集准确率73.0%与三位放射科医生平均准确率61.7%相比无统计学显著差异(p=0.059),对2组的阳性预测值高于观察者(85.7% vs. 35.0-48.4%)。

要点

  • CT影像组学模型可区分肺腺癌三个预后亚型组,开发集AUC 0.892,测试集AUC 0.895。
  • 0组与2组之间鉴别AUC最高达0.984,模型对2组阳性预测值85.7%,高于观察者的35.0-48.4%。
  • 模型测试集准确率73.0%与三位放射科医生平均61.7%相比无统计学显著差异(p=0.059)。

核心结论

  • 基于CT的影像组学模型对肺腺癌主要亚型预后分组的分类性能与放射科医生相当。

研究设计与样本

  • 回顾性研究,纳入2010年3月至2016年6月间993例浸润性肺腺癌患者,从增强CT分割提取718个影像组学特征,893例组成模型开发集,100例作为测试集,采用LASSO方法筛选特征,以组织学主要亚型预后分组为参考标准。

诊断标准与关键数值

  • 模型区分三组的AUC在开发集为0.892、测试集为0.895;两两鉴别中0组 vs 2组AUC最高为0.984;测试集准确率73.0%,三位放射科医生(胸部CT经验分别为6、7、19年)平均准确率61.7%(p=0.059);2组阳性预测值模型85.7%,观察者35.0-48.4%。

临床应用与阅片要点

  • 作者结论认为CT影像组学模型对肺腺癌主要亚型预后分组的分类性能与放射科医生相当;模型对2组的阳性预测值高于观察者。

局限性

  • 模型测试集准确率与三位放射科医生平均准确率比较p=0.059,未达统计学显著。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a model for differentiating the predominant subtype-based prognostic groups of lung adenocarcinoma using CT radiomic features, and to validate its performance in comparison with radiologists' assessments.

METHODS: A total of 993 patients presenting with invasive lung adenocarcinoma between March 2010 and June 2016 were identified. Predominant histologic subtypes were categorized into three groups according to their prognosis (group 0: lepidic; group 1: acinar/papillary; group 2: solid/micropapillary). Seven hundred eighteen radiomic features were extracted from segmented lung cancers on contrast-enhanced CT. A model-development set was formed from the images of 893 patients, while 100 image sets were reserved for testing. A least absolute shrinkage and selection operator method was used for feature selection. Performance of the radiomic model was evaluated using receiver operating characteristic curve analysis, and accuracy on the test set was compared with that of three radiologists with varying experiences (6, 7, and 19 years in chest CT).

RESULTS: Our model differentiated the three groups with areas under the curve (AUCs) of 0.892 and 0.895 on the development and test sets, respectively. In pairwise discrimination, the AUC was highest for group 0 vs. 2 (0.984). The accuracy of the model on the test set was higher than the averaged accuracy of the three radiologists without statistical significance (73.0% vs. 61.7%, p = 0.059). For group 2, the model achieved higher PPV than the observers (85.7% vs. 35.0-48.4%).

CONCLUSIONS: Predominant subtype-based prognostic groups of lung adenocarcinoma were classified by a CT-based radiomic model with comparable performance to radiologists.

KEY POINTS: • A CT-based radiomic model differentiated three prognosis-based subtype groups of lung adenocarcinoma with areas under the curve (AUCs) of 0.892 and 0.895 on development and test sets, respectively. • The CT-based radiomic model showed near perfect discrimination between group 0 and group 2 (AUCs, 0.984-1.000). • The accuracy of the CT-based radiomic model was comparable to the averaged accuracy of the three radiologists with 6, 7, and 19 years of clinical experience in chest CT (73.0% vs. 61.7%, p = 0.059), achieving a higher positive predictive value for group 2 than the observers (85.7% vs. 35.0-48.4%).

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Park S, Lee SM, Noh HN, et al. Differentiation of predominant subtypes of lung adenocarcinoma using a quantitative radiomics approach on CT. Eur Radiol. 2020. PMID: 32300970. doi:10.1007/s00330-020-06805-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。