文献速递胸部腹部CT

CT纹理分析联合淋巴结轴比检测食管癌淋巴结转移

Combined CT texture analysis and nodal axial ratio for detection of nodal metastasis in esophageal cancer.
PubMed 文献 · Br J Radiol · 2020-04-15

回顾性分析38例食管鳞状细胞癌患者78枚淋巴结(40枚转移、38枚良性)的增强胸部CT,计算淋巴结轴比并提取CT纹理分析参数(峰度、熵、偏度),采用Logistic回归联合显著纹理特征与轴比鉴别转移性与良性淋巴结,联合模型敏感度87.5%、特异度65.8%、AUROC 0.855。

要点

  • 转移性淋巴结平均轴比高于良性淋巴结(0.81±0.2 vs 0.71±0.1,p=0.005),即转移性淋巴结更圆。
  • 中尺度熵鉴别转移性与良性淋巴结的AUROC为0.802(p<0.001),敏感度85.0%、特异度63.2%。
  • 轴比联合细尺度熵与细尺度峰度的Logistic回归模型敏感度87.5%、特异度65.8%、AUROC 0.855(p<0.001)。

核心结论

  • CT纹理分析特征联合淋巴结轴比有潜力鉴别转移性与良性淋巴结,并提高食管鳞状细胞癌淋巴结转移的检出敏感度。
  • 联合CT纹理分析与淋巴结轴比使CT诊断食管癌转移性淋巴结的敏感度提高至87.5%。

研究设计与样本

  • 回顾性分析38例食管鳞状细胞癌患者的增强胸部CT图像,共78枚淋巴结(40枚转移、38枚良性)。
  • 计算淋巴结轴比(短轴/长轴直径),并使用商用软件(TexRAD)以细、中、粗空间滤波器提取峰度、熵、偏度等CT纹理分析参数。
  • 将显著纹理特征与淋巴结轴比组合作为预测变量纳入Logistic回归模型,以受试者工作特征曲线下面积(AUROC)分析模型性能。

关键影像表现/征象

  • 转移性淋巴结平均轴比显著高于良性淋巴结(0.81±0.2 vs 0.71±0.1,p=0.005;敏感度82.5%,特异度47.4%),即转移性淋巴结显著更圆。
  • 转移性淋巴结的熵(所有滤波器)和峰度(细、中滤波器)均值显著高于良性淋巴结(均p<0.05)。

诊断标准与关键数值

  • 轴比(短轴/长轴直径)鉴别转移性与良性淋巴结:敏感度82.5%、特异度47.4%。
  • 中尺度熵鉴别转移性与良性淋巴结:AUROC 0.802(p<0.001),敏感度85.0%、特异度63.2%。
  • 轴比联合细尺度熵与细尺度峰度的二元Logistic回归模型:敏感度87.5%、特异度65.8%、AUROC 0.855(p<0.001)。

临床应用与阅片要点

  • 阅片时可关注淋巴结轴比,转移性淋巴结形态更趋圆(轴比更高)。
  • CT纹理分析中熵和峰度在转移性与良性淋巴结间存在差异,中尺度熵鉴别性能较好。
  • 联合轴比与细尺度纹理特征(熵、峰度)的Logistic回归模型可提高诊断敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the accuracy of a combination of CT texture analysis (CTTA) and nodal axial ratio to detect metastatic lymph nodes (LNs) in esophageal squamous cell carcinoma (ESCC).

METHODS: The contrast-enhanced chest CT images of 78 LNs (40 metastasis, 38 benign) from 38 patients with ESCC were retrospectively analyzed. Nodal axial ratios (short-axis/long-axis diameter) were calculated. CCTA parameters (kurtosis, entropy, skewness) were extracted using commercial software (TexRAD) with fine, medium, and coarse spatial filters. Combinations of significant texture features and nodal axial ratios were entered as predictors in logistic regression models to differentiate metastatic from benign LNs, and the performance of the logistic regression models was analyzed using the area under the receiver operating characteristic curve (AUROC).

RESULTS: The mean axial ratio of metastatic LNs was significantly higher than that of benign LNs (0.81 ± 0.2 vs 0.71 ± 0.1, p = 0.005; sensitivity 82.5%, specificity 47.4%); namely, significantly more round than benign. The mean values of the entropy (all filters) and kurtosis (fine and medium) of metastatic LNs were significantly higher than those of benign LNs (all, p < 0.05). Medium entropy showed the best performance in the AUROC analysis with 0.802 (p < 0.001; sensitivity 85.0%, specificity 63.2%). A binary logistic regression analysis combining the nodal axial ratio, fine entropy, and fine kurtosis identified metastatic LNs with 87.5% sensitivity and 65.8% specificity (AUROC = 0.855, p < 0.001).

CONCLUSION: The combination of CTTA features and the axial ratio of LNs has the potential to differentiate metastatic from benign LNs and improves the sensitivity for detection of LN metastases in ESCC.

ADVANCES IN KNOWLEDGE: The combination of CTTA and nodal axial ratio has improved CT sensitivity (up to 87.5%) for the diagnosis of metastatic LNs in esophageal cancer.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee HN, Kim JI, Shin SY, et al. Combined CT texture analysis and nodal axial ratio for detection of nodal metastasis in esophageal cancer. Br J Radiol. 2020. PMID: 32242741. doi:10.1259/bjr.20190827

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。