三维超短回波时间MRI用于囊性纤维化的功能性肺成像

Three-dimensional Ultrashort Echo Time MRI for Functional Lung Imaging in Cystic Fibrosis.
PubMed 文献 · Radiology · 2020-04-28

这项前瞻性研究纳入20例囊性纤维化患者和10例健康对照,采用单次屏气三维超短回波时间序列行功能性肺MRI,计算归一化通气四分位距(IQRN)和全呼气期信号强度(SIN)。患者IQRN高于对照(0.66±0.16 vs 0.50±0.04,P=.007),且IQRN与肺清除指数(LCI)相关(r=0.90)。

要点

  • 囊性纤维化患者IQRN高于健康对照(0.66±0.16 vs 0.50±0.04,P=.007),提示通气不均。
  • IQRN与肺清除指数(LCI)相关(r=0.90;95%CI:0.69,0.96;P<.001)。
  • 全呼气期SIN在患者中低于对照(0.34±0.08 vs 0.39±0.03,P=.03)。

核心结论

  • 三维超短回波时间MRI可在数次屏气内实现囊性纤维化患者通气不均的功能成像。

研究设计与样本

  • 前瞻性研究,2018年5月至2019年6月纳入20例囊性纤维化患者(平均年龄17岁±9,12名男性)和10例健康对照(24岁±8,5名男性)。
  • 采用原型单次屏气三维超短回波时间序列行功能性肺MRI,并以肺功能检查(PFT)为参照。
  • 从正常吸气和正常呼气采集数据计算部分通气(FV),将每体素FV归一化至全肺均值(FVN),计算归一化通气四分位距(IQRN)作为通气异质性指标。
  • 评估全呼气期超短回波时间信号强度(SIN,归一化至主动脉血),比较患者与对照的MRI指标,并在患者中与标准肺清除指数(LCI)及PFT行Spearman相关分析。

关键影像表现/征象

  • 囊性纤维化患者IQRN高于健康对照(均值0.66±0.16 vs 0.50±0.04,P=.007)。
  • 囊性纤维化患者全呼气期SIN低于健康对照(0.34±0.08 vs 0.39±0.03,P=.03)。

诊断标准与关键数值

  • IQRN与第1秒用力呼气容积占用力肺活量比值相关(r=-0.70;95%CI:-0.92,-0.28;P<.001)。
  • IQRN与呼气中期流量25%相关(r=0.78;95%CI:-0.95,-0.39;P<.001)。
  • IQRN与通气不均参数肺清除指数(LCI)相关(r=0.90;95%CI:0.69,0.96;P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background In cystic fibrosis (CF), recurrent imaging and pulmonary function tests (PFTs) are needed for the assessment of lung function during disease management. Purpose To assess the clinical feasibility of pulmonary three-dimensional ultrashort echo time (UTE) MRI at breath holding for quantitative image analysis of ventilation inhomogeneity and hyperinflation in CF compared with PFT. Materials and Methods In this prospective study from May 2018 to June 2019, participants with CF and healthy control participants underwent PFTs and functional lung MRI by using a prototypical single breath-hold three-dimensional UTE sequence. Fractional ventilation (FV) was calculated from acquired data in normal inspiration and normal expiration. FV of each voxel was normalized to the whole lung mean (FVN), and interquartile range of normalized ventilation (IQRN; as a measure of ventilation heterogeneity) was calculated. UTE signal intensity (SI) was assessed in full expiration (SIN, normalized to aortic blood). Obtained metrics were compared between participants with CF and control participants. For participants with CF, MRI metrics were correlated with the standard lung clearance index (LCI) and PFT. Mann-Whitney U tests and Spearman correlation were used for statistical analysis. Results Twenty participants with CF (mean age, 17 years ± 9 [standard deviation]; 12 men) and 10 healthy control participants (24 years ± 8; five men) were included. IQRN was higher for participants with CF than for control participants (mean, 0.66 ± 0.16 vs 0.50 ± 0.04, respectively; P = .007). In the 20 participants with CF, IQRN correlated with obstruction markers forced expiratory volume in 1 second-to-forced vital capacity ratio (r = -0.70; 95% confidence interval [CI]: -0.92, -0.28; P < .001), mean expiratory flow 25% (r = 0.78; 95% CI: -0.95, -0.39; P < .001), and with the ventilation inhomogeneity parameter LCI (r = 0.90; 95% CI: 0.69, 0.96; P < .001). Mean SIN in full expiration was lower in participants with CF than in control participants (0.34 ± 0.08 vs 0.39 ± 0.03, respectively; P = .03). Conclusion Three-dimensional ultrashort echo time MRI in the lungs allowed for functional imaging of ventilation inhomogeneity within a few breath holds in patients with cystic fibrosis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Wielpütz in this issue.

来源:Radiology,查看原文。版权归原作者所有。