入院胸部CT上的通气良好肺预测COVID-19肺炎的不良结局
该回顾性研究分析了2020年2月17日至3月10日急诊入院并接受胸部CT的236例COVID-19肺炎患者,评估入院CT上通气良好肺(WAL)量化对重症监护室(ICU)入住或死亡的预测价值。结果显示,目测%V-WAL<73%、软件%S-WAL<71%和绝对容积VOL-WAL<2.9 L均为ICU入住或死亡的预测因子,含量化指标的模型AUC(0.86)优于仅临床参数模型(AUC=0.83)。
要点
- 入院CT目测通气良好肺百分比<73%预示ICU入住或死亡风险增高(OR 5.4)。
- 软件量化通气良好肺百分比<71%和绝对容积<2.9 L同样为不良结局预测因子。
- 包含CT量化指标的预测模型AUC为0.86,优于仅临床参数模型(AUC=0.83)。
核心结论
- 在确诊COVID-19肺炎患者中,目测或软件量化CT肺异常范围可预测ICU入住或死亡。
研究设计与样本
- 回顾性分析2020年2月17日至3月10日急诊入院并接受胸部CT的患者,最终纳入236例(女性59/123,占25%;中位年龄68岁)。
诊断标准与关键数值
- 目测通气良好肺百分比(%V-WAL)<73%:OR 5.4(95%CI 2.7, 10.8),P<.001。
- 软件量化通气良好肺百分比(%S-WAL)<71%:OR 3.8(95%CI 1.9, 7.5),P<.001。
- 通气良好肺绝对容积(VOL-WAL)<2.9 L:OR 2.6(95%CI 1.2, 5.8),P<.01。
- 仅临床参数模型AUC=0.83;含CT量化指标的三个模型AUC均为0.86。
- 含%V-WAL<73%和VOL-WAL<2.9 L的模型与仅临床参数模型相比性能更优,两者P=.04。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background CT of patients with severe acute respiratory syndrome coronavirus 2 disease depicts the extent of lung involvement in coronavirus disease 2019 (COVID-19) pneumonia. Purpose To determine the value of quantification of the well-aerated lung (WAL) obtained at admission chest CT to determine prognosis in patients with COVID-19 pneumonia. Materials and Methods Imaging of patients admitted at the emergency department between February 17 and March 10, 2020 who underwent chest CT were retrospectively analyzed. Patients with negative results of reverse-transcription polymerase chain reaction for severe acute respiratory syndrome coronavirus 2 at nasal-pharyngeal swabbing, negative chest CT findings, and incomplete clinical data were excluded. CT images were analyzed for quantification of WAL visually (%V-WAL), with open-source software (%S-WAL), and with absolute volume (VOL-WAL). Clinical parameters included patient characteristics, comorbidities, symptom type and duration, oxygen saturation, and laboratory values. Logistic regression was used to evaluate the relationship between clinical parameters and CT metrics versus patient outcome (intensive care unit [ICU] admission or death vs no ICU admission or death). The area under the receiver operating characteristic curve (AUC) was calculated to determine model performance. Results The study included 236 patients (59 of 123 [25%] were female; median age, 68 years). A %V-WAL less than 73% (odds ratio [OR], 5.4; 95% confidence interval [CI]: 2.7, 10.8; P < .001), %S-WAL less than 71% (OR, 3.8; 95% CI: 1.9, 7.5; P < .001), and VOL-WAL less than 2.9 L (OR, 2.6; 95% CI: 1.2, 5.8; P < .01) were predictors of ICU admission or death. In comparison with clinical models containing only clinical parameters (AUC = 0.83), all three quantitative models showed better diagnostic performance (AUC = 0.86 for all models). The models containing %V-WAL less than 73% and VOL-WAL less than 2.9 L were superior in terms of performance as compared with the models containing only clinical parameters (P = .04 for both models). Conclusion In patients with confirmed coronavirus disease 2019 pneumonia, visual or software quantification of the extent of CT lung abnormality were predictors of intensive care unit admission or death. © RSNA, 2020 Online supplemental material is available for this article.
引用
- Colombi D, Bodini FC, Petrini M, et al. Well-aerated Lung on Admitting Chest CT to Predict Adverse Outcome in COVID-19 Pneumonia. Radiology. 2020. PMID: 32301647. doi:10.1148/radiol.2020201433
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。