文献速递神经CTMR

血栓切除术后缺血性脑病灶的机器学习体积测量:缺血性卒中患者的前瞻性诊断准确性研究

Machine learning volumetry of ischemic brain lesions on CT after thrombectomy-prospective diagnostic accuracy study in ischemic stroke patients.
PubMed 文献 · Neuroradiology · 2020-04-22

这项前瞻性单中心观察性研究纳入45例CT血管造影证实前循环闭塞并接受血管内血栓切除术的患者,比较Brainomix软件在NCCT上自动测量的缺血病灶体积与DWI上手动测量的缺血病灶体积的一致性。结果显示两种测量在特定ASPECTS区域检测随访缺血改变方面具有高相关性和准确性,Brainomix自动测量的NCCT缺血病灶体积可能被视为有价值的影像学结局指标。

要点

  • Brainomix自动NCCT缺血病灶体积与DWI手动测量在特定ASPECTS区域检测随访缺血改变方面具有高相关性和准确性。
  • TICI 2b-3组Brainomix中位缺血病灶体积为23 ml(IQR 15-39 ml),DWI中位缺血病灶体积为11.5 ml(IQR 7-32 ml)。
  • 临床结局良好(mRS 0-2)患者的DWI缺血病灶体积显著低于mRS≥3患者(10 mL vs 59 mL,p=0.002)。

关键影像表现/征象

  • TICI 2b-3组Brainomix中位缺血病灶体积为23 ml(IQR 15-39 ml),DWI中位缺血病灶体积为11.5 ml(IQR 7-32 ml)。
  • TICI 0-2a组NCCT缺血病灶体积为39 ml(IQR 18-62 ml),DWI缺血病灶体积为30 ml(IQR 11-105 ml)。
  • 临床结局良好(mRS 0-2)患者的DWI缺血病灶体积显著低于mRS≥3患者(10 mL vs 59 mL,p=0.002)。
  • Brainomix缺血病灶体积测量也观察到类似趋势(21 mL vs 39 mL,p=0.012)。

诊断标准与关键数值

  • 采用McNemar检验评估敏感度和特异度。
  • 采用Somer's delta检验一致与不一致ASPECTS区域之间的差异。
  • 采用Bland-Altman图比较Brainomix与DWI缺血病灶体积的差异。

临床应用与阅片要点

  • Brainomix软件自动测量的NCCT缺血病灶体积与DWI手动测量在特定ASPECTS区域检测随访缺血改变方面具有高相关性和准确性,作者认为其可能被视为有价值的影像学结局指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ischemic lesion volume (ILV) is an important radiological predictor of functional outcome in patients with anterior circulation stroke. Our aim was to assess the agreement between automated ILV measurements on NCCT using the Brainomix software and manual ILV measurements on diffusion-weighted imaging (DWI).

METHODS: This was a prospective single-center observational study of patients with CT angiography (CTA) proven anterior circulation occlusion treated with endovascular thrombectomy (May 2018 to May 2019). NCCT ILV was measured automatically by the Brainomix software. DWI ILV was measured manually. The McNemar's test was used to test sensitivity and specificity. The Somer's delta was used to test the differences between concordant and discordant ASPECTS regions. The Bland-Altman plot was calculated to compare the differences between Brainomix and DWI ILVs.

RESULTS: Forty-five patients were included. Median Brainomix ILV was 23 ml (interquartile range [IQR], 15-39 ml), and median DWI ILV was 11.5 ml (IQR, 7-32 ml) in the TICI 2b-3 group. In the TICI 0-2a, the NCCT ILV was 39 ml (IQR, 18-62 ml) and DWI ILV was 30 (IQR, 11-105 ml). The DWI ILVs in patients with good clinical outcome (mRS 0-2) was significantly lower compared with patients with mRS ≥ 3 (10 mL vs 59 mL, p = 0.002). Similar trend was observed for Brainomix ILV measurements (21 mL vs 39 mL, p = 0.012). There was a high correlation and accuracy in the detection of follow-up ischemic changes in particular ASPECTS regions.

CONCLUSION: NCCT ILV measured automatically by the Brainomix software might be considered a valuable radiological outcome measure.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Kral J, Cabal M, Kasickova L, et al. Machine learning volumetry of ischemic brain lesions on CT after thrombectomy-prospective diagnostic accuracy study in ischemic stroke patients. Neuroradiology. 2020. PMID: 32318775. doi:10.1007/s00234-020-02419-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。