指南与共识乳腺MR

新辅助部分乳腺照射试验中MRI上原发乳腺肿瘤勾画的共识

Consensus on Contouring Primary Breast Tumors on MRI in the Setting of Neoadjuvant Partial Breast Irradiation in Trials.
指南 / 共识 · Pract Radiat Oncol · 2020-04-18

国际团队经3次会议制定MRI勾画原发乳腺肿瘤的专家共识:GTV按增强MRI注射对比剂后1至2分钟所见的全部肿瘤及瘤内标记勾画,并均匀外扩20 mm形成CTV(排除皮肤和胸壁);两轮勾画中GTV的CI为0.28至0.77,CTV的CI为0.77至0.94。

要点

  • GTV勾画范围为增强MRI注射对比剂后1至2分钟所见的全部肿瘤,瘤内标记物需包括在内。
  • CTV由GTV均匀外扩20 mm生成,并排除皮肤和胸壁。
  • 肿瘤毛刺延伸、邻近血管或瘤内标记、腺体组织强化增高时GTV观察者间差异最大。

核心结论

  • 试验中MRI上原发乳腺肿瘤勾画已达成专家共识,在统一20 mm GTV至CTV外扩边界下CTV观察者间差异低。

研究设计与样本

  • 由国际团队中经验丰富的乳腺放射肿瘤科医生和专攻乳腺的放射科医生经3次会议制定勾画指南共识。
  • 第一次会议通过讨论并勾画2例制定指南草案;第二次会议6名乳腺放射肿瘤科医生按草案对10例早期乳腺癌(cT1N0)患者勾画GTV。
  • 第二次会议将GTV均匀外扩20 mm生成CTV并排除皮肤和胸壁,复核勾画分歧并据此明确指南。
  • 第三次会议5名放射肿瘤科医生按共识指南重新勾画6例,用广义一致性指数(CI)评估GTV和CTV的观察者间差异。

关键影像表现/征象

  • GTV观察者间差异最大的情况为肿瘤毛刺延伸、肿瘤附近有血管或瘤内有标记物、腺体乳腺组织强化增高。

诊断标准与关键数值

  • GTV勾画标准为增强MRI注射对比剂后1至2分钟扫描上所有可见肿瘤,瘤内插入标记物时须包括该标记。
  • CTV由GTV均匀外扩20 mm生成,排除皮肤和胸壁。
  • 两次勾画合计GTV均值范围为0.19至2.44 cm3。
  • 两次勾画合计GTV的CI范围为0.28至0.77,CTV的CI范围为0.77至0.94。

临床应用与阅片要点

  • 在试验场景中按共识于增强MRI注射对比剂后1至2分钟图像上勾画全部可见肿瘤并包含瘤内标记。
  • 对肿瘤毛刺延伸、邻近血管或瘤内标记、腺体组织强化增高的病例,GTV勾画需关注观察者间差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Our purpose was to present and evaluate expert consensus on contouring primary breast tumors on magnetic resonance imaging (MRI) in the setting of neoadjuvant partial breast irradiation in trials.

METHODS AND MATERIALS: Expert consensus on contouring guidelines for target definition of primary breast tumors on contrast-enhanced MRI in trials was developed by an international team of experienced breast radiation oncologists and a dedicated breast radiologist during 3 meetings. At the first meeting, draft guidelines were developed through discussing and contouring 2 cases. At the second meeting 6 breast radiation oncologists delineated gross tumor volume (GTV) in 10 patients with early-stage breast cancer (cT1N0) according to draft guidelines. GTV was expanded isotropically (20 mm) to generate clinical target volume (CTV), excluding skin and chest wall. Delineations were reviewed for disagreement and guidelines were clarified accordingly. At the third meeting 5 radiation oncologists redelineated 6 cases using consensus-based guidelines. Interobserver variation of GTV and CTV was assessed using generalized conformity index (CI). CI was calculated as the sum of volumes each pair of observers agreed upon, divided by the sum of encompassing volumes for each pair of observers.

RESULTS: For the 2 delineation sessions combined, mean GTV ranged between 0.19 and 2.44 cm3, CI for GTV ranged between 0.28 and 0.77, and CI for CTV between 0.77 and 0.94. The largest interobserver variation in GTV delineations was observed in cases with extended tumor spiculae, blood vessels near or markers within the tumor, or with increased enhancement of glandular breast tissue. Consensus-based guidelines stated to delineate all visible tumors on contrast enhanced-MRI scan 1 to 2 minutes after contrast injection and if a marker was inserted in the tumor to include this.

CONCLUSIONS: Expert-based consensus on contouring primary breast tumors on MRI in trials has been reached. This resulted in low interobserver variation for CTV in the context of a uniform 20 mm GTV to CTV expansion margin.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Vasmel JE, Groot Koerkamp ML, Kirby AM, et al. Consensus on Contouring Primary Breast Tumors on MRI in the Setting of Neoadjuvant Partial Breast Irradiation in Trials. Pract Radiat Oncol. 2020. PMID: 32315784. doi:10.1016/j.prro.2020.03.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。