文献速递技术与安全CTDRPET

2006-2016年美国放射学与核医学检查的患者暴露:检查量与有效剂量

Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States: Procedure Volume and Effective Dose for the Period 2006-2016.
PubMed 文献 · Radiology · 2020-03-17

使用国际辐射防护委员会第60号出版物组织权重因子估算:2006年人均有效剂量2.9 mSv,2016年2.3 mSv。

要点

  • 人均有效剂量从2006年2.9 mSv降至2016年2.3 mSv。

诊断标准与关键数值

  • 使用国际辐射防护委员会第60号出版物组织权重因子估算:2006年人均有效剂量2.9 mSv,2016年2.3 mSv。
  • 2006年集体有效剂量885000人-希沃特,2016年755000人-希沃特。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Comprehensive assessments of the frequency and associated doses from radiologic and nuclear medicine procedures are rarely conducted. The use of these procedures and the population-based radiation dose increased remarkably from 1980 to 2006. Purpose To determine the change in per capita radiation exposure in the United States from 2006 to 2016. Materials and Methods The U.S. National Council on Radiation Protection and Measurements conducted a retrospective assessment for 2016 and compared the results to previously published data for the year 2006. Effective dose values for procedures were obtained from the literature, and frequency data were obtained from commercial, governmental, and professional society data. Results In the United States in 2006, an estimated 377 million diagnostic and interventional radiologic examinations were performed. This value remained essentially the same for 2016 even though the U.S. population had increased by about 24 million people. The number of CT scans performed increased from 67 million to 84 million, but the number of other procedures (eg, diagnostic fluoroscopy) and nuclear medicine procedures decreased from 17 million to 13.5 million. The number of dental radiographic and dental CT examinations performed was estimated to be about 320 million in 2016. Using the tissue-weighting factors from Publication 60 of the International Commission on Radiological Protection, the U.S. annual individual (per capita) effective dose from diagnostic and interventional medical procedures was estimated to have been 2.9 mSv in 2006 and 2.3 mSv in 2016, with the collective doses being 885 000 and 755 000 person-sievert, respectively. Conclusion The trend from 1980 to 2006 of increasing dose from medical radiation has reversed. Estimated 2016 total collective effective dose and radiation dose per capita dose are lower than in 2006. © RSNA, 2020 See also the editorial by Einstein in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Mettler FA, Mahesh M, Bhargavan-Chatfield M, et al. Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States: Procedure Volume and Effective Dose for the Period 2006-2016. Radiology. 2020. PMID: 32181730. doi:10.1148/radiol.2020192256

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。