基于FDG-PET影像数据集深度学习分析预测口咽鳞状细胞癌患者HPV状态:一项假设生成研究
本研究纳入120例治疗前接受FDG-PET/CT的口咽鳞状细胞癌患者,分为训练集90例和验证集30例,用深度学习建立HPV状态诊断模型。验证集中模型敏感度0.83、特异度0.83、准确度0.83,高于两名放射科医师的视觉评估(准确度0.67和0.6),差异有统计学意义。作者认为该模型可作为判断HPV状态的辅助工具。
要点
- 深度学习模型在验证集判断口咽鳞癌HPV状态的准确度为0.83。
- 两名放射科医师视觉评估准确度分别为0.67和0.6,低于模型。
- 该研究为假设生成研究,模型定位为辅助工具。
诊断标准与关键数值
- 验证集中深度学习模型判断HPV状态:敏感度0.83、特异度0.83、阳性预测值0.88、阴性预测值0.77、诊断准确度0.83。
- 读者1视觉评估判断HPV状态:敏感度0.78、特异度0.5、阳性预测值0.7、阴性预测值0.6、诊断准确度0.67。
- 读者2视觉评估判断HPV状态:敏感度0.56、特异度0.67、阳性预测值0.71、阴性预测值0.5、诊断准确度0.6。
- 卡方检验显示深度学习与放射科医师诊断准确度之间差异有统计学意义(读者1 P=0.016,读者2 P=0.008)。
临床应用与阅片要点
- 作者认为基于FDG-PET的深度学习模型可作为确定口咽鳞癌HPV状态的辅助工具之一。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the diagnostic accuracy of imaging-based deep learning analysis to differentiate between human papillomavirus (HPV) positive and negative oropharyngeal squamous cell carcinomas (OPSCCs) using FDG-PET images.
METHODS: One hundred and twenty patients with OPSCC who underwent pretreatment FDG-PET/CT were included and divided into the training 90 patients and validation 30 patients cohorts. In the training session, 2160 FDG-PET images were analyzed after data augmentation process by a deep learning technique to create a diagnostic model to discriminate between HPV-positive and HPV-negative OPSCCs. Validation cohort data were subsequently analyzed for confirmation of diagnostic accuracy in determining HPV status by the deep learning-based diagnosis model. In addition, two radiologists evaluated the validation cohort image-data to determine the HPV status based on each tumor's imaging findings.
RESULTS: In deep learning analysis with training session, the diagnostic model using training dataset was successfully created. In the validation session, the deep learning diagnostic model revealed sensitivity of 0.83, specificity of 0.83, positive predictive value of 0.88, negative predictive value of 0.77, and diagnostic accuracy of 0.83, while the visual assessment by two radiologists revealed 0.78, 0.5, 0.7, 0.6, and 0.67 (reader 1), and 0.56, 0.67, 0.71, 0.5, and 0.6 (reader 2), respectively. Chi square test showed a significant difference between deep learning- and radiologist-based diagnostic accuracy (reader 1: P = 0.016, reader 2: P = 0.008).
CONCLUSIONS: Deep learning diagnostic model with FDG-PET imaging data can be useful as one of supportive tools to determine the HPV status in patients with OPSCC.
引用
- Fujima N, Andreu-Arasa VC, Meibom SK, et al. Prediction of the human papillomavirus status in patients with oropharyngeal squamous cell carcinoma by FDG-PET imaging dataset using deep learning analysis: A hypothesis-generating study. Eur J Radiol. 2020. PMID: 32171912. doi:10.1016/j.ejrad.2020.108936
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。