文献速递腹部泌尿生殖技术与安全CT

20个国家血尿与尿路结石CT协议及辐射剂量的实践比较

CT protocols and radiation doses for hematuria and urinary stones: Comparing practices in 20 countries.
PubMed 文献 · Eur J Radiol · 2020-02-29

国际原子能机构调查欧洲地区20国51家医院1276例患者,比较CT尿路造影、尿路结石CT和常规腹盆CT的方案与剂量。多数机构采用3-6期尿路造影(80%,中位DLP 1793-3618 mGy·cm),其剂量为2期方案的2.4-4.9倍;尿路结石CT中位DLP 516 mGy·cm显著低于其他两种方案。仅少数机构(4/13)对尿路结石使用低剂量CT。

要点

  • 多数机构采用3-6期CT尿路造影(80%),中位DLP 1793-3618 mGy·cm,为2期方案(20%,740 mGy·cm)的2.4-4.9倍(p<0.0001)。
  • 52%患者接受3-5期常规腹盆CT(中位DLP 1574-2945 mGy·cm),37%接受单期常规CT(676 mGy·cm)。
  • 尿路结石CT中位DLP 516 mGy·cm,显著低于尿路造影和常规腹盆CT(p<0.0001);仅4/13机构使用低剂量CT。

诊断标准与关键数值

  • 多数机构(80%)使用3-6期CT尿路造影协议,中位DLP 1793-3618 mGy·cm;2期协议占20%,中位DLP 740 mGy·cm,3-6期协议剂量为2期协议的2.4-4.9倍(p<0.0001)。
  • 52%患者接受3-5期常规腹盆CT(中位DLP 1574-2945 mGy·cm),37%接受单期常规CT(中位DLP 676 mGy·cm)。
  • 尿路结石CT中位DLP 516 mGy·cm,显著低于其他两种CT协议的中位DLP(p<0.0001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Patients with hematuria and renal colic often undergo CT scanning. The purpose of our study was to assess variations in CT protocols and radiation doses for evaluation of hematuria and urinary stones in 20 countries.

METHOD: The International Atomic Energy Agency (IAEA) surveyed practices in 51 hospitals from 20 countries in the European region according to the IAEA Technical cooperation classification and obtained following information for three CT protocols (urography, urinary stones, and routine abdomen-pelvis CT) for 1276 patients: patient information (weight, clinical indication), scanner information (scan vendor, scanner name, number of detector rows), scan parameters (such as number of phases, scan start and end locations, mA, kV), and radiation dose descriptors (CTDIvol, DLP). Two radiologists assessed the appropriateness of clinical indications and number of scan phases using the ESR Referral Guidelines and ACR Appropriateness Criteria. Descriptive statistics and Student's t tests were performed.

RESULTS: Most institutions use 3-6 phase CT urography protocols (80 %, median DLP 1793-3618 mGy.cm) which were associated with 2.4-4.9-fold higher dose compared to 2-phase protocol (20 %, 740 mGy.cm) (p < 0.0001). Likewise, 52 % patients underwent 3-5 phase routine abdomen- pelvis CT (1574-2945 mGy.cm) as opposed to 37 % scanned with a single-phase routine CT (676 mGy.cm). The median DLP for urinary stones CT (516 mGy.cm) were significantly lower than the median DLP for the other two CT protocols (p < 0.0001).

CONCLUSIONS: Few institutions (4/13) use low dose CT for urinary stones. There are substantial variations in CT urography and routine abdomen-pelvis CT protocols result in massive radiation doses (up to 2945-3618 mGy.cm).

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gershan V, Homayounieh F, Singh R, et al. CT protocols and radiation doses for hematuria and urinary stones: Comparing practices in 20 countries. Eur J Radiol. 2020. PMID: 32171911. doi:10.1016/j.ejrad.2020.108923

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。