文献速递介入泌尿生殖DSA

女性放射学逆行输尿管支架置换:单中心回顾性研究

Radiological retrograde ureteric stent exchange in women: a single-centre review.
PubMed 文献 · Clin Radiol · 2020-03-08

该单中心回顾性研究评估改良导丝环技术用于逆行输尿管支架置换的安全性和有效性。2012年1月至2016年12月间,79例患者共取出270枚支架、置换238枚,支架置换成功率为234/238(98%)。作者结论认为该技术有效、快速且易于用日常介入设备完成,并可结合输尿管成形术。

要点

  • 支架置换成功率为234/238(98%),失败原因包括入路丢失、解剖扭曲无法圈套和支架严重结壳。
  • 252/270(93%)病例使用改良圈套器取出支架,18例(7%)使用其他圈套装置。
  • 支架置换平均透视时间为573秒,平均皮肤剂量为12,494 DAP/mGy•cm2。

诊断标准与关键数值

  • 支架置换成功率为234/238(98%)。
  • 支架取出中,252/270(93%)使用改良圈套器,18例(7%)使用其他圈套装置。
  • 支架置换平均每枚支架透视时间为573秒,平均皮肤剂量为12,494 DAP/mGy•cm2。

临床应用与阅片要点

  • 作者结论认为,透视引导下改良圈套环技术行逆行输尿管支架置换有效、快速,且易于用日常介入设备完成。
  • 作者指出该技术可与输尿管成形术联合,可能有助于患者最终达到无支架状态。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the safety and efficacy of modified wire loop technique for retrograde stent exchange.

MATERIALS AND METHODS: All patients were from the KK Women and Children's Hospital where there is no on-site urology service. Patients were identified retrospectively from the institutional radiological information system (RIS) database. In total, 270 stents were removed and 238 replaced for 79 patients between January 2012 to December 2016. Success rates for stent removal and exchange as well as skin dose and fluoroscopy time were assessed.

RESULTS: Stent exchange was successful in 234/238 (98%) of cases. Failure was due to loss of access (one case), inability to snare stent due to distorted anatomy (two cases), and extensive encrustation of stent (one case). In 252/270 (93%) cases, stent was removed using modified snare while in 18 (7%) cases, other snare devices were used. Average fluoroscopy time per stent for stent exchange was 573 seconds and average skin dose was 12,494 DAP/mGy•cm2.

CONCLUSION: Fluoroscopy-guided retrograde ureteric stent exchange using the modified snare loop technique is effective, quick, and can be performed easily with equipment used in daily intervention practice. It may also be coupled with ureteroplasty, which may help the patient achieve eventual stent-free status.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Lai AL, Choong M, Toh LMHW, et al. Radiological retrograde ureteric stent exchange in women: a single-centre review. Clin Radiol. 2020. PMID: 32156418. doi:10.1016/j.crad.2020.02.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。