文献速递神经外周血管MRDSASPECT

颅外颈动脉狭窄患者液体衰减反转恢复序列高信号血管与脑血流动力学的关系

Cerebral hemodynamics associated with fluid-attenuated inversion recovery hyperintense vessels in patients with extracranial carotid artery stenosis.
PubMed 文献 · Neuroradiology · 2020-03-09

本研究纳入2011年3月至2018年10月在本院接受颈动脉支架置入术的173例慢性颅外颈动脉狭窄患者,比较FLAIR高信号血管(FHVs)与DSA所见及乙酰唑胺激发SPECT脑血流动力学变化的关系。92例(53.2%)存在FHVs,FHV阳性者狭窄更重、软脑膜侧支更多、脑血管反应性(CVR)显著降低,而同侧静息脑血流量(rCBF)与同侧CVR是FHVs的独立预测因素。

要点

  • 颅外颈动脉狭窄患者中53.2%(92/173)出现FLAIR高信号血管征。
  • FHV阳性者狭窄程度更重且软脑膜侧支血管更多(均P<0.01)。
  • FHV阳性者CVR较FHV阴性者显著降低,而rCBF无显著差异。

核心结论

  • 在颅外颈动脉狭窄患者中,脑血流动力学指标尤其是同侧rCBF和同侧CVR与FHVs的存在相关。

研究设计与样本

  • 研究纳入2011年3月至2018年10月在本院接受颈动脉支架置入术的慢性颅外颈动脉狭窄患者173例。
  • 采用DSA评估脑血管造影所见,采用乙酰唑胺激发SPECT定量测量大脑中动脉供血区rCBF和CVR。
  • 采用多因素logistic回归分析识别FHVs的独立预测因素。

关键影像表现/征象

  • FLAIR序列上可见高信号血管征(FHVs),FHV阳性者狭窄程度更重且软脑膜侧支血管更多(均P<0.01)。
  • FHV阳性者CVR较FHV阴性者显著降低(P<0.01),而两组间rCBF无显著差异。

诊断标准与关键数值

  • 多因素logistic回归显示同侧rCBF和同侧CVR是FHVs的显著预测因素(P<0.01)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Fluid-attenuated inversion recovery hyperintense vessels (FHVs) are linked to sluggish or disordered blood flow. The purpose of this study is to compare FHVs with digital subtraction angiography (DSA) findings and cerebral hemodynamic changes on acetazolamide challenge SPECT and to determine the clinical and imaging metrics associated with FHVs in patients with extracranial carotid artery stenosis (ECAS).

METHODS: The subjects were patients with chronic ECAS who underwent carotid artery stenting in our department between March 2011 and October 2018. Relationships of FHVs with age, sex, medical history, cerebral angiographic findings using DSA, and quantitative values of cerebral blood flow (CBF) were examined. The resting CBF (rCBF) and cerebrovascular reactivity (CVR) in the middle cerebral artery territory were measured quantitatively using SPECT with acetazolamide challenge. We used multivariate logistic regression analysis to identify independent predictors of FHVs.

RESULTS: Of 173 patients included, 92 (53.2%) had FHVs. Patients with FHVs had more severe stenosis (P < 0.01) and more leptomeningeal collateral vessels (P < 0.01). FHV-positive cases had significantly reduced CVR compared with FHV-negative cases (P < 0.01), although there was no significant difference in rCBF between FHV-positive and FHV-negative cases. Logistic regression analysis showed that ipsilateral rCBF and ipsilateral CVR were significant predictors for FHVs (P < 0.01).

CONCLUSION: In patients with ECAS, cerebral hemodynamic metrics, especially ipsilateral rCBF and ipsilateral CVR, are associated with the presence of FHVs.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Nishimoto T, Ishihara H, Oka F, et al. Cerebral hemodynamics associated with fluid-attenuated inversion recovery hyperintense vessels in patients with extracranial carotid artery stenosis. Neuroradiology. 2020. PMID: 32152648. doi:10.1007/s00234-020-02385-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。