超声检测内侧半月板突出可预测放射性膝关节骨关节炎的发生风险:一项5年队列研究
该5年队列研究纳入472名参与者共944个膝关节,基线超声测量内侧半月板突出(MME),以Kellgren-Lawrence分级(KLG)评估放射性膝关节骨关节炎(ROA)。基线非ROA膝中7.5%发生iROA,基线ROA膝中12.7%发生pROA;ROC曲线确定4 mm为检测iROA和pROA风险的最佳截断值。多因素回归显示4 mm截断值与iROA(aOR 6.746)和pROA(aOR 5.993)均显著相关。
要点
- 基线超声测量的内侧半月板突出(MME)越大,5年内发生放射性膝关节骨关节炎的风险越高。
- 4 mm是预测iROA和pROA风险的最佳截断值,右膝AUC分别为0.639和0.750,左膝分别为0.641和0.863。
- MME 4 mm截断值与iROA(aOR 6.746)和pROA(aOR 5.993)的患病率均显著相关。
关键影像表现/征象
- 基线超声测量内侧半月板突出(MME)以mm为单位。
- 基线574个非ROA膝中43膝(7.5%)发生iROA;基线370个ROA膝中47膝(12.7%)发生pROA。
诊断标准与关键数值
- 放射性KOA(ROA)定义为KLG ≥ 2;iROA定义为基线KLG 0-1在5年内增至KLG ≥ 2;pROA定义为基线KLG 2-3在5年内恶化至更高分级。
- 4 mm为检测iROA风险的最佳截断值(右膝AUC 0.639;左膝AUC 0.641)。
- 4 mm为检测pROA风险的最佳截断值(右膝AUC 0.750;左膝AUC 0.863)。
- MME 4 mm截断值与iROA患病率显著相关(B 1.909;p ≤ 0.001;aOR 6.746)。
- MME 4 mm截断值与pROA患病率显著相关(B 1.791;p ≤ 0.001;aOR 5.993)。
临床应用与阅片要点
- 超声测量内侧半月板突出(MME)可用于识别有发生放射性膝关节骨关节炎风险的患者。
- 4 mm为检测iROA和pROA风险的最佳截断值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To clarify the relationship between the baseline value of medial meniscus extrusion (MME) and the radiographic change of knee osteoarthritis (KOA) through a 5-year follow-up.
METHODS: Overall, 472 participants and 944 knees were eligible. MME (mm) was measured at the baseline, and KOA was radiographically evaluated at both baseline and 5-year follow-up by Kellgren-Lawrence grade (KLG). Radiographic KOA (ROA) was defined as the knee showing KLG ≥ 2. Incident ROA (iROA) was defined if the baseline KLG of 0-1 increased to KLG ≥ 2 in 5 years. Progressive ROA (pROA) was defined if the baseline KLG of 2-3 worsened to a higher grade in 5 years. Receiver operating characteristic (ROC) curve and generalized estimating equations were used for analysis.
RESULTS: Of 574 non-ROA knees at the baseline, 43 knees (7.5%) developed iROA; of 370 ROA knees, 47 knees (12.7%) developed pROA. Based on the ROC curves, 4 mm was the optimal cutoff to detect the risk of iROA (area under curve [AUC] 0.639 [right knee]; AUC 0.641 [left knee]) and that of pROA (AUC 0.750 [right knee]; AUC 0.863 [left knee]). Multiple regression analysis showed that the 4-mm cutoff of MME was significantly associated with both the prevalence of iROA (regression coefficient [B] 1.909; p ≤ 0.001; adjusted odds ratio [aOR] 6.746) and that of pROA (B 1.791; p ≤ 0.001; aOR 5.993).
CONCLUSIONS: On ultrasonography, the participants with more extruded medial meniscus showed a higher prevalence of both iROA and pROA. Ultrasonography could identify patients who had a risk of developing KOA.
KEY POINTS: • Through a 5-year follow-up, the current cohort study was conducted to clarify the relationship between the baseline value of medial meniscus extrusion (MME) and the radiographic change of knee osteoarthritis (KOA). • More extruded medial meniscus evaluated by ultrasonography was associated with the development of radiographic KOA. • Ultrasonography could identify the patients who had a risk of developing KOA, and the 4-mm cutoff of MME was optimal to detect this risk.
引用
- Chiba D, Sasaki E, Ota S, et al. US detection of medial meniscus extrusion can predict the risk of developing radiographic knee osteoarthritis: a 5-year cohort study. Eur Radiol. 2020. PMID: 32140818. doi:10.1007/s00330-020-06749-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。