PubMed 文献 · Skeletal Radiol · 2020-03-07

研究纳入27例疑似踝关节软骨病变患者,序贯行平板CT(FPCT)、多排CT(MDCT)和1.5 T MR关节造影,以MDCT关节造影为参考标准评估216个软骨区域。FPCT检测软骨缺损的敏感度97%、特异度95%、准确率96%,均优于MR关节造影的69%、94%和87%;FPCT与MDCT几乎完全一致(κ=0.87),MR为中等一致(κ=0.60)。作者认为FPCT对踝关节软骨缺损检测的准确率优于1.5 T MR关节造影,对计划行踝关节软骨专用成像的患者应考虑FPCT。

要点

  • FPCT检测踝关节软骨缺损的敏感度97%、准确率96%,高于1.5 T MR关节造影的69%和87%。
  • FPCT与MDCT关节造影几乎完全一致(κ=0.87),MR仅为中等一致(κ=0.60)。
  • FPCT诊断信心评分2.9/3,高于MDCT的2.7/3和MR的2.3/3。

核心结论

  • FPCT对踝关节软骨缺损检测的准确率优于1.5 T MR关节造影,作者建议对计划行踝关节软骨专用成像的患者考虑FPCT。

研究设计与样本

  • 前瞻性研究纳入27例疑似关节软骨病变患者,注射稀释钆与碘比醇混合物后行踝关节造影,并序贯接受FPCT、MDCT和1.5 T MR成像。
  • 由两名肌肉骨骼放射科医师在盲法下随机共识评估FPCT、MDCT和MR关节造影图像,每个踝关节分别评估8个关节软骨区域:距骨内侧关节面、距骨内侧滑车、距骨外侧滑车、距骨外侧关节面、胫骨内踝、胫骨内侧穹窿、胫骨外侧穹窿和腓骨外踝。
  • 以MDCT关节造影 assessments 为参考标准,比较FPCT和MR在216个软骨区域中的表现。

诊断标准与关键数值

  • FPCT检测软骨缺损:敏感度97%、特异度95%、准确率96%。
  • MR关节造影检测软骨缺损:敏感度69%、特异度94%、准确率87%。
  • FPCT与MDCT关节造影几乎完全一致(κ=0.87),MR与MDCT关节造影中等一致(κ=0.60)。
  • 平均诊断信心评分:FPCT 2.9/3,MDCT 2.7/3,MR 2.3/3。

临床应用与阅片要点

  • 作者建议,对计划行踝关节软骨专用成像的患者应考虑FPCT。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of this study was to compare the diagnostic performance of flat-panel computed tomography (FPCT) arthrography for cartilage defect detection in the ankle joint to direct magnetic resonance (MR) arthrography using multidetector computed tomography (MDCT) arthrography as the reference standard.

METHODS: Twenty-seven patients with specific suspicion of articular cartilage lesion underwent ankle arthrography with injection of a mixture of diluted gadolinium and iobitridol and were examined consecutively with the use of FPCT, MDCT, and 1.5 T MR imaging. FPCT, MDCT, and MR arthrography examinations were blinded and randomly evaluated by two musculoskeletal radiologists in consensus. In each ankle, eight articular cartilage areas were assessed separately: medial talar surface, medial talar trochlea, lateral talar trochlea, lateral talar surface, tibial malleolus, medial tibial plafond, lateral tibial plafond, and fibular malleolus. Findings at FPCT and MR were compared with MDCT assessments in 216 cartilage areas.

RESULTS: For the detection of cartilage defects, FPCT demonstrated a sensitivity of 97%, specificity of 95%, and accuracy of 96%; and MR arthrography showed a sensitivity of 69%, specificity of 94%, and accuracy of 87%. FPCT and MR arthrography presented almost perfect agreement (κ = 0.87) and moderate agreement (κ = 0.60), respectively, with MDCT arthrography. Mean diagnostic confidence was higher for FPCT (2.9/3) than for MR (2.3/3) and MDCT (2.7/3) arthrography.

CONCLUSIONS: FPCT demonstrated better accuracy than did 1.5 T MR arthrography for cartilage defect detection in the ankle joint. Therefore, FPCT should be considered in patients scheduled for dedicated imaging of ankle articular cartilage.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Pagliano S, Chemouni D, Guggenberger R, et al. Flat-panel CT arthrography for cartilage defect detection in the ankle joint: first results in vivo. Skeletal Radiol. 2020. PMID: 32146486. doi:10.1007/s00256-020-03398-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。