文献速递骨肌儿科影像MR

幼年特发性关节炎:弥散加权MRI在膝关节关节炎评估中的应用

Juvenile Idiopathic Arthritis: Diffusion-weighted MRI in the Assessment of Arthritis in the Knee.
PubMed 文献 · Radiology · 2020-03-10

本前瞻性研究纳入45例幼年特发性关节炎或疑似患者,以多学科团队临床诊断为参考标准,评估弥散加权成像(DWI)检测关节炎的准确性,并与增强MRI比较显示滑膜炎症的能力。DWI检测关节炎的敏感度为93%、特异度为81%;与增强MRI相比,DWI检测滑膜炎症的敏感度为92%、特异度为78%,两种方法在37/45例(82%)中评分一致。

要点

  • DWI检测膝关节关节炎的敏感度为93%(95%CI:64%,100%),特异度为81%(95%CI:62%,92%)。
  • 以增强MRI为参考标准,DWI检测滑膜炎症的敏感度为92%、特异度为78%。
  • DWI与增强MRI对滑膜炎症的评分在37/45例(82%)中一致。

核心结论

  • DWI在幼年特发性关节炎或疑似患儿中检测关节炎准确,且与增强MRI显示滑膜炎症的结果一致。
  • 作者认为,在该患者群体中DWI可能替代增强MRI用于滑膜炎症成像。

研究设计与样本

  • 机构审查委员会批准的前瞻性研究,2015年12月至2018年12月纳入45例幼年特发性关节炎或疑似患者(7例男孩、38例女孩;中位年龄14岁,四分位距12-16岁)。
  • 所有受试者接受3.0-T膝关节增强前后MRI并附加DWI序列。
  • 临床参考标准由多学科团队根据临床、实验室和影像学表现(除外DWI)判定关节炎存在与否。
  • 两名放射科医师在不知晓所有临床数据的情况下分别对两组数据集评分:数据集1为增强前后序列(增强MRI),数据集2为增强前及DWI序列(DWI)。

诊断标准与关键数值

  • DWI检测关节炎的敏感度为93%(14例关节炎患者中13例正确分类;95%CI:64%,100%),特异度为81%(31例无关节炎患者中25例正确分类;95%CI:62%,92%)。
  • 以增强MRI为参考标准,DWI检测滑膜炎症的敏感度为92%(13例中12例;95%CI:62%,100%),特异度为78%(32例中25例;95%CI:60%,90%)。
  • DWI与增强MRI对滑膜炎症的评分在37/45例(82%)中一致。

临床应用与阅片要点

  • 作者认为,DWI可能替代增强MRI用于该患者群体的滑膜炎症成像。
  • 原文未据此给出其他临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Diffusion-weighted imaging (DWI) can depict the inflamed synovial membrane in arthritis. Purpose To study the diagnostic accuracy of DWI for the detection of arthritis compared with the clinical reference standard and to compare DWI to contrast material-enhanced MRI for the detection of synovial inflammation. Materials and Methods In this institutional review board-approved prospective study, 45 participants with juvenile idiopathic arthritis (JIA) or suspected of having JIA (seven boys, 38 girls; median age, 14 years [interquartile range, 12-16 years]) were included between December 2015 and December 2018. Study participants underwent pre- and postcontrast 3.0-T MRI of the knee with an additional DWI sequence. For the clinical reference standard, a multidisciplinary team determined the presence or absence of arthritis on the basis of clinical, laboratory, and imaging findings (excluding DWI). Two data sets were scored by two radiologists blinded to all clinical data; data set 1 contained pre- and postcontrast sequences (contrast-enhanced MRI), and data set 2 contained precontrast and DWI sequences (DWI). Diagnostic accuracy was determined by comparing the scores of the DWI data set to those of the clinical reference standard. Second, DWI was compared with contrast-enhanced MRI regarding detection of synovial inflammation. Results Sensitivity for detection of arthritis for DWI was 93% (13 of the 14 participants with arthritis were correctly classified with DWI; 95% confidence interval [CI]: 64%, 100%) and specificity was 81% (25 of 31 participants without arthritis were correctly classified with DWI; 95% CI: 62%, 92%). Scores for synovial inflammation at DWI and contrast-enhanced MRI agreed in 37 of 45 participants (82%), resulting in a sensitivity of 92% (12 of 13 participants; 95% CI: 62%, 100%) and specificity of 78% (25 of 32 participants; 95% CI: 60%, 90%) with DWI when contrast-enhanced MRI was considered the reference standard. Conclusion Diffusion-weighted imaging (DWI) was accurate in detecting arthritis in pediatric participants with juvenile idiopathic arthritis (JIA) or suspected of having JIA and showed agreement with contrast-enhanced MRI. The results indicate that DWI could replace contrast-enhanced MRI for imaging of synovial inflammation in this patient group. © RSNA, 2020 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Barendregt AM, Mazzoli V, van Gulik EC, et al. Juvenile Idiopathic Arthritis: Diffusion-weighted MRI in the Assessment of Arthritis in the Knee. Radiology. 2020. PMID: 32154774. doi:10.1148/radiol.2020191685

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。