文献速递乳腺MR

局部晚期乳腺癌不同增强后时间点肿瘤分割分析:定量DCE-MRI参数变异性的可能来源

Tumor segmentation analysis at different post-contrast time points: A possible source of variability of quantitative DCE-MRI parameters in locally advanced breast cancer.
PubMed 文献 · Eur J Radiol · 2020-02-21

前瞻性纳入40例患者42个局部晚期乳腺癌病灶,在3T乳腺DCE-MRI的四個增强后时间点手动分割强化肿瘤并提取参数。Ktrans、Kep和iAUC在最早可识别病灶的时间点(TP1)最高,自TP2至TP4逐渐降低;观察者内信度好至优(ICC 0.894–0.990),观察者间信度中等至优(ICC 0.770–0.942),TP1和TP2提取的Ktrans和Kep观察者间信度显著高于TP3和TP4。作者建议在固定时间点(最好是最早时间点)进行肿瘤勾画以获得可靠可比的DCE-MRI数据。

要点

  • Ktrans、Kep和iAUC在最早可识别病灶的增强后时间点(TP1)最高,自TP2至TP4逐渐降低。
  • TP1和TP2提取的Ktrans和Kep观察者间信度显著高于TP3和TP4。
  • 作者建议在固定时间点(最好是最早时间点)进行肿瘤勾画以提取可靠可比的DCE-MRI数据。

关键影像表现/征象

  • 在最早可识别病灶的增强后时间点(TP1)放置ROI提取的Ktrans、Kep和iAUC显著更高,并自TP2至TP4逐渐降低。

诊断标准与关键数值

  • 观察者内信度好至优,ICC为0.894至0.990;观察者间信度中等至优,ICC为0.770至0.942。
  • TP1和TP2提取的Ktrans和Kep观察者间信度显著高于TP3和TP4。

临床应用与阅片要点

  • 作者建议在固定时间点(最好是最早时间点)进行肿瘤勾画,以提取可靠且可比的DCE-MRI数据。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: to assess if tumor segmentation analysis performed at different post-contrast time points (TPs) on dynamic images could influence the extraction of dynamic contrast enhanced (DCE)-MRI parameters in locally advanced breast cancer (LABC), and potentially represent a source of variability.

METHOD: forty patients with forty-two LABC lesions were prospectively enrolled and underwent breast DCE-MRI examination at 3 T. On post-processed dynamic images, enhancing tumor lesions were manually segmented at four different TPs: at the first post-contrast dynamic image in which the lesion was appreciable (TP 1) and at 1, 5 and 10 min after contrast-agent administration (TPs 2, 3 and 4, respectively) and corresponding DCE-MRI parameters were extracted. Friedman's test followed by Bonferroni-adjusted Wilcoxon signed rank test for post-hoc analysis was used to compare DCE-MRI parameters. Intra- and inter-observer reliability of DCE-MRI parameters measurements was assessed using the Intraclass Correlation Coefficient (ICC) analysis.

RESULTS: Ktrans, Kep and iAUC were significantly higher when extracted from ROIs placed at TP1 and progressively decreased from TP 2-4. The intra-observer reliability ranged from good to excellent (ICC's: 0.894 to 0.990). The inter-observer reliability varied from moderate to excellent (0.770 to 0.942). The inter-observer reliability was significantly higher for Ktrans and Kep extracted at TPs1 and 2 as compared to TPs 3 and 4.

CONCLUSIONS: A significant variability of DCE-MRI quantitative parameters occurs when tumor segmentation is performed at different TPs. We suggest to performing tumor delineation at an established TP, preferably the earliest, in order to extract reliable and comparable DCE-MRI data.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Romeo V, Cavaliere C, Imbriaco M, et al. Tumor segmentation analysis at different post-contrast time points: A possible source of variability of quantitative DCE-MRI parameters in locally advanced breast cancer. Eur J Radiol. 2020. PMID: 32145597. doi:10.1016/j.ejrad.2020.108907

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。