多参数磁共振成像筛查乳腺极度致密女性中计算机辅助诊断以减少假阳性诊断
本研究基于DENSE试验首轮筛查数据,开发并评估多参数乳腺MRI的计算机辅助诊断(CAD)模型,用于预测BI-RADS 3和4病变为良性。全多参数模型可将425例假阳性BI-RADS 3/4病变中的176例(41.5%)分类为良性,而未漏诊恶性肿瘤,从而可能减少活检或重复MRI的召回。
要点
- 在乳腺极度致密女性MRI筛查中,BI-RADS 3和4病变的假阳性率高达87.3%(425/487)。
- 全多参数CAD模型可将41.5%(176/425)的假阳性BI-RADS 3/4病变正确分类为良性,且未漏诊恶性肿瘤。
- 若使用全多参数CAD辅助转诊,活检或重复MRI的召回可从425/487(87.3%)降至311/487(63.9%)。
核心结论
- 针对乳腺极度致密女性筛查中BI-RADS 3和4病变的多参数CAD有潜力减少假阳性诊断,并在不漏诊癌症的情况下减少活检数量。
研究设计与样本
- 研究使用DENSE试验首轮筛查的连续数据,该试验在2011年12月至2016年1月期间纳入8家参与医院的4783名50至75岁、乳腺X线摄影阴性且乳腺极度致密的无症状女性,采用多参数MRI筛查。
- MRI协议包括5个序列:无脂肪抑制T1加权成像、扩散加权成像、高空间分辨率T1加权对比增强成像、高时间分辨率T1加权对比增强成像和T2加权成像。
- 共454名女性的525个病变被评分为BI-RADS 3(n=202)、4(n=304)或5(n=19),其中组织学检查显示444个良性、81个恶性;BI-RADS 5病变仅用于训练。
- CAD包括特征提取和病变分类两个阶段;第一组特征基于所有多参数序列提取49个候选预测因子(46个自动计算图像特征加3个临床特征:年龄、体重指数和BI-RADS评分),第二组基于简化MRI协议常用序列提取36个图像特征加相同的3个临床特征。
- 采用10折交叉验证开发Ridge回归模型,并通过准确度测量曲线和受试者工作特征分析评估模型性能。
诊断标准与关键数值
- 在转诊至额外MRI或活检的BI-RADS 3和4病变中,425/487(87.3%)为假阳性。
- 全多参数模型将425个假阳性BI-RADS 3和4病变中的176个(41.5%)分类为良性,且未漏诊恶性病变。
- 简化协议模型将425个假阳性BI-RADS 3和4病变中的111个(26.2%)分类为良性,且未漏诊恶性病变。
- 若使用全多参数CAD辅助转诊,活检或重复MRI的召回可从425/487(87.3%)降至311/487(63.9%);若使用简化协议,可降至376/487(77.2%)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To reduce the number of false-positive diagnoses in the screening of women with extremely dense breasts using magnetic resonance imaging (MRI), we aimed to predict which BI-RADS 3 and BI-RADS 4 lesions are benign. For this purpose, we use computer-aided diagnosis (CAD) based on multiparametric assessment.
MATERIALS AND METHODS: Consecutive data were used from the first screening round of the DENSE (Dense Tissue and Early Breast Neoplasm Screening) trial. In this trial, asymptomatic women with a negative screening mammography and extremely dense breasts were screened using multiparametric MRI. In total, 4783 women, aged 50 to 75 years, enrolled and were screened in 8 participating hospitals between December 2011 and January 2016. In total, 525 lesions in 454 women were given a BI-RADS 3 (n = 202), 4 (n = 304), or 5 score (n = 19). Of these lesions, 444 were benign and 81 were malignant on histologic examination.The MRI protocol consisted of 5 different MRI sequences: T1-weighted imaging without fat suppression, diffusion-weighted imaging, T1-weighted contrast-enhanced images at high spatial resolution, T1-weighted contrast-enhanced images at high temporal resolution, and T2-weighted imaging. A machine-learning method was developed to predict, without deterioration of sensitivity, which of the BI-RADS 3- and BI-RADS 4-scored lesions are actually benign and could be prevented from being recalled. BI-RADS 5 lesions were only used for training, because the gain in preventing false-positive diagnoses is expected to be low in this group. The CAD consists of 2 stages: feature extraction and lesion classification. Two groups of features were extracted: the first based on all multiparametric sequences, the second based only on sequences that are typically used in abbreviated MRI protocols. In the first group, 49 features were used as candidate predictors: 46 were automatically calculated from the MRI scans, supplemented with 3 clinical features (age, body mass index, and BI-RADS score). In the second group, 36 image features and the same 3 clinical features were used. Each group was considered separately in a machine-learning model to differentiate between benign and malignant lesions. We developed a Ridge regression model using 10-fold cross validation. Performance of the models was analyzed using an accuracy measure curve and receiver-operating characteristic analysis.
RESULTS: Of the total number of BI-RADS 3 and BI-RADS 4 lesions referred to additional MRI or biopsy, 425/487 (87.3%) were false-positive. The full multiparametric model classified 176 (41.5%) and the abbreviated-protocol model classified 111 (26.2%) of the 425 false-positive BI-RADS 3- and BI-RADS 4-scored lesions as benign without missing a malignant lesion.If the full multiparametric CAD had been used to aid in referral, recall for biopsy or repeat MRI could have been reduced from 425/487 (87.3%) to 311/487 (63.9%) lesions. For the abbreviated protocol, it could have been 376/487 (77.2%).
CONCLUSIONS: Dedicated multiparametric CAD of breast MRI for BI-RADS 3 and 4 lesions in screening of women with extremely dense breasts has the potential to reduce false-positive diagnoses and consequently to reduce the number of biopsies without missing cancers.