对比增强能谱乳腺X线摄影与超声在有症状致密型乳腺患者中的诊断效能比较
该前瞻性研究纳入2017年5月1日至9月30日间115例致密型乳腺有症状患者的131个病灶,以组织病理学为金标准,比较对比增强能谱乳腺X线摄影(CESM)与超声(US)的诊断效能。
要点
- 致密型乳腺有症状患者中,CESM与US诊断效能相当,各指标差异无统计学意义。
- CESM的AUC为0.917,US为0.884,两者比较P=0.225。
- CESM假阳性8例、假阴性4例;US假阳性12例、假阴性6例。
核心结论
- 在有症状的致密型乳腺女性中,CESM与US的诊断效能相当。
- 对于CESM可检出的病灶,常规加做US的价值存疑。
研究设计与样本
- 前瞻性研究,经当地伦理委员会批准,收集2017年5月1日至2017年9月30日有症状乳腺患者数据。
- 选取致密型乳腺且有病理结果者,共纳入115例患者的131个病灶。
- 由一名放射科医师按乳腺影像报告和数据系统(BI-RADS)对CESM和US结果分类,并与组织病理学结果对照。
- 采用卡方检验比较CESM与US的诊断效能,并获得两种影像方法的受试者工作特征曲线。
诊断标准与关键数值
- CESM:敏感度93.8%、特异度88.1%、阳性预测值88.2%、阴性预测值93.7%、准确率90.8%。
- US:敏感度90.6%、特异度82.1%、阳性预测值82.9%、阴性预测值90.2%、准确率86.3%。
- 敏感度、特异度、阳性预测值、阴性预测值、准确率的P值分别为0.687、0.388、0.370、0.702、0.238。
- CESM的AUC为0.917,US的AUC为0.884,两者差异无统计学意义(P=0.225)。
临床应用与阅片要点
- CESM与US诊断效能相当,阅片时可依据两者各自表现综合判断。
- CESM发现假阳性8例、假阴性4例;US发现假阳性12例、假阴性6例。
- 对CESM可检出的病灶,常规加做US的价值存疑。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) versus ultrasonography (US) in symptomatic patients with dense breasts, while using histology as the gold standard.
MATERIALS AND METHODS: After obtaining approval from the local ethics board, this prospective study collected data from patients with symptomatic breasts who underwent CESM and US examinations from May 1, 2017 to September 30, 2017. We then selected those with dense breasts and pathological results as our sample population. Both CESM and US results were classified by a radiologist through the Breast Imaging Reporting and Data System, and the results were compared with their corresponding histological results. The chi-square test was conducted to compare the diagnostic performance of CESM and US, and the receiver operating characteristic curves for the two imaging modalities were obtained.
RESULTS: A total of 131 lesions from 115 patients with dense breasts were included in this study. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were 93.8%, 88.1%, 88.2%, 93.7%, and 90.8% for CESM, and 90.6%, 82.1%, 82.9%, 90.2%, and 86.3% for US, respectively. The p values for sensitivity, specificity, PPV, NPV, and accuracy were 0.687, 0.388, 0.370, 0.702, and 0.238, respectively. The area under the curve of CESM (0.917) was comparable with that of US (0.884); however, the differences between CESM and US were not statistically significant (p = 0.225). Eight false-positive cases and 4 false-negative cases for breast cancer were found in CESM, while 12 false-positive cases and 6 false-negative cases were found in US.
CONCLUSION: The diagnostic performances of CESM and US are comparable in symptomatic women with dense breasts; however, the routine use of additional US imaging is questionable for lesions that can be detected by CESM.