定量超声监测乳腺肿瘤对新辅助化疗的反应:临床扫描仪间结果比较
本研究比较两台临床超声系统在局部晚期乳腺癌患者新辅助化疗反应监测中的定量超声与纹理特征估计一致性。两台系统间数据变异小,肿瘤反应预测结果一致性良好,McNemar检验未显示显著差异。组织异质性为参数测量的主导因素,超声系统波束特性差异对纹理特征影响较小。
要点
- 两台临床超声系统间定量超声与纹理特征数据变异小,肿瘤反应预测一致性良好。
- 组织异质性为定量超声参数测量的主导特征,系统波束特性差异影响较小。
- McNemar检验示两台系统肿瘤反应预测结果无显著差异。
核心结论
- 研究结果表明在不同超声成像平台间实现可靠且一致的定量超声与纹理分析具有潜力。
研究设计与样本
- 研究比较两台临床超声系统在局部晚期乳腺癌患者新辅助化疗反应监测中的定量超声与纹理特征估计一致性。
- 原文未报告样本量、中心数及具体设备型号。
诊断标准与关键数值
- 原文未报告敏感度、特异度、AUC、阈值或分级标准。
临床应用与阅片要点
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Quantitative ultrasound (QUS) techniques have been demonstrated to detect cell death in vitro and in vivo. Recently, multi-feature classification models have been incorporated into QUS texture-feature analysis methods to increase further the sensitivity and specificity of detecting treatment response in locally advanced breast cancer patients. To effectively incorporate these analytic methods into clinical applications, QUS and texture-feature estimations should be independent of data acquisition systems. The study here investigated the consistencies of QUS and texture-feature estimation techniques relative to several factors. These included the ultrasound system properties, the effects of tissue heterogeneity and the effects of these factors on the monitoring of response to neoadjuvant chemotherapy. Specifically, tumour-response-detection performance based on QUS and texture parameters using two clinical ultrasound systems was compared. Observed variations in data between the systems were small and the results exhibited good agreement in tumour response predictions obtained from both ultrasound systems. The results obtained in this study suggest that tissue heterogeneity was a dominant feature in the parameters measured with the two different ultrasound systems; whereas differences in ultrasound system beam properties only exhibited a minor impact on texture features. The McNemar statistical test performed on tumour response prediction results from the two systems did not reveal significant differences. Overall, the results in this study demonstrate the potential to achieve reliable and consistent QUS and texture-based analyses across different ultrasound imaging platforms.
引用
- Sannachi L, Gangeh M, Naini AS, et al. Quantitative Ultrasound Monitoring of Breast Tumour Response to Neoadjuvant Chemotherapy: Comparison of Results Among Clinical Scanners. Ultrasound Med Biol. 2020. PMID: 32111456. doi:10.1016/j.ultrasmedbio.2020.01.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。