剪切波弹性成像在鉴别特发性肉芽肿性乳腺炎与乳腺癌中的作用
研究纳入经影像引导活检确诊的乳腺癌80例与特发性肉芽肿性乳腺炎88例,评估剪切波弹性成像(SWE)及常规超声BI-RADS分类的鉴别能力。结果显示乳腺炎病灶剪切波速度均值2.5±1.17 m/s,显著低于乳腺癌的5.2±0.76 m/s,以4.1 m/s为截断值的敏感度97.5%、特异度93%、AUC 0.94。
要点
- 特发性肉芽肿性乳腺炎剪切波速度均值2.5±1.17 m/s,显著低于乳腺癌的5.2±0.76 m/s。
- 以4.1 m/s为截断值鉴别两者,敏感度97.5%、特异度93%、准确率95.2%、AUC 0.94。
- 常规超声BI-RADS评分在较多乳腺炎病例中不够低,不足以避免活检。
关键影像表现/征象
- 剪切波在较硬组织中传播较快、在较软组织中传播较慢,SWE利用聚焦辐射力、无需手动加压。
- 特发性肉芽肿性乳腺炎病灶剪切波速度均值为2.5±1.17 m/s,乳腺癌为5.2±0.76 m/s。
- 乳腺癌组的BI-RADS评分和SWE评分均显著高于特发性肉芽肿性乳腺炎组(p<0.01)。
- 与剪切波速度值和SWE评分不同,许多特发性肉芽肿性乳腺炎病例的BI-RADS评分不够低,无法避免活检。
诊断标准与关键数值
- 以剪切波速度4.1 m/s为截断值鉴别特发性肉芽肿性乳腺炎与乳腺癌,敏感度97.5%、特异度93%、阳性预测值92.6%、阴性预测值97.6%、准确率95.2%(p<0.01)。
- 剪切波速度诊断能力的AUC为0.94。
- SWE评分采用Tsukuba评分系统,BI-RADS分类依据常规超声同步评定。
临床应用与阅片要点
- 阅片时可结合剪切波速度值和Tsukuba SWE评分辅助鉴别特发性肉芽肿性乳腺炎与乳腺癌。
- 常规超声BI-RADS评分在部分特发性肉芽肿性乳腺炎病例中不够低,单凭BI-RADS可能无法避免活检。
- 作者认为在临床实践中实施SWE方法可能减少不必要的活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Shear wave elastography (SWE) uses focused radiation forces without manual compression and is intrinsically not operator dependent. Shear waves travel faster in stiffer tissue and slower in softer tissues.
PURPOSE: The purpose of this study was to determine the role of SWE, imaging, and point measurements in differentiating idiopathic granulomatous mastitis (IGM) from breast cancer.
MATERIAL AND METHODS: Data from 168 patients diagnosed with breast cancer (n= 80) or IGM (n = 88) through image-guided biopsy were included in the study. All patients were evaluated with SWE followed by conventional ultrasonography (US). Shear wave velocity (Vs) and the SWE scoring system (Tsukuba) were used to evaluate lesions, which were classified synchronously according to the Breast Imaging Reporting and Data System (BI-RADS) by using conventional US. Lesion size and BI-RADS scores were recorded, and the scores of the lesions were compared between the two groups. The diagnostic capacity of the Vs value was measured by the area under the receiver operating characteristic curve (AUC, 0.94).
RESULTS: The mean age was 37 ± 9 years for patients with IGM and 49 ± 13 years for patients with breast cancer. Both Breast Imaging Report and Data System (BI-RADS) and SWE scores were significantly higher in breast cancer patients than in IGM patients (p < 0.01). However, unlike the Vs values and SWE scores, the BI-RADS scores were not low enough in many IGM cases to avoid biopsy. The mean Vs value of IGM lesions was 2.5 ± 1.17 m/s, which was significantly lower than that of breast cancer (5.2 ± 0.76 m/s, p < 0.01). The cut-off value was 4.1 m/s, and the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 97.5%, 93%, 92.6%, 97.6%, and 95.2%, respectively (p < 0.01).
CONCLUSION: SWE has high sensitivity and specificity in differentiating IGM from breast cancer with a lower SWE score and Vs value. Implementing this approach in clinical practice could reduce the number of unnecessary biopsies.
引用
- Makal GB, Güvenç İ. The Role of Shear Wave Elastography in Differentiating Idiopathic Granulomatous Mastitis From Breast Cancer. Acad Radiol. 2020. PMID: 32217054. doi:10.1016/j.acra.2020.02.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。