文献速递腹部泌尿生殖CT

快速kV切换双能CT能否准确判定肾结石成分

Can Dual Energy CT with Fast kV-Switching Determine Renal Stone Composition Accurately?
PubMed 文献 · Acad Radiol · 2020-03-23

研究将15枚肾结石置入猪肾水槽模型,用快速kV切换双能CT与常规协议扫描,以傅里叶变换红外光谱为金标准。双能CT对12枚可分析结石中10枚成分判定正确(83%绝对一致,k=0.69),临床CT与显微CT所测结石直径无统计学差异(p=0.051)。作者认为快速kV切换双能CT可能发展为低剂量体内识别和分类肾结石的临床工具。

要点

  • 双能CT判定肾结石成分与红外光谱的绝对一致率为83%(k=0.69)。
  • 15枚结石中3枚成分无法用扫描仪软件判定。
  • 临床CT与显微CT所测结石平均直径无统计学差异(p=0.051)。

核心结论

  • 快速kV切换双能CT可能发展为低剂量临床工具,用于体内识别和分类肾结石以支持临床决策。
  • 12枚可分析结石中10枚成分被双能CT正确识别(83%绝对一致,k=0.69)。

研究设计与样本

  • 体外模型研究:将15枚肾结石置入猪肾并置于水槽中,行快速kV切换双能CT与常规协议扫描。
  • 以傅里叶变换红外光谱测定的结石化学成分为参考标准。
  • 用扫描仪软件测量每枚结石的有效原子序数,结石直径测量重复两次以评估组内变异,并与显微CT实测直径比较。

关键影像表现/征象

  • 3枚结石(1枚磷酸钙、2枚碳酸磷灰石)的化学成分无法用扫描仪软件判定。

诊断标准与关键数值

  • 双能CT成分判定与红外光谱的绝对一致率为83%(k=0.69),基于12枚可分析结石中的10枚正确识别。
  • 临床CT与显微CT所测平均结石直径无统计学差异(p=0.051)。

临床应用与阅片要点

  • 作者认为快速kV切换双能CT可能发展为低剂量体内识别和分类肾结石的临床工具,以支持临床决策。
  • 扫描仪软件对部分成分(磷酸钙、碳酸磷灰石)可能无法判定,本研究中15枚结石有3枚未能判定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To determine whether a single source computed tomography (CT) system utilizing fast kV switching and low dose settings can characterize (diameter and chemical composition) renal stones accurately when compared infrared spectroscopy.

MATERIALS AND METHODS: The chemical composition of 15 renal stones was determined using Fourier transform infrared spectroscopy. The stones were inserted into a porcine kidney and placed within a water tank for CT scanning using both fast kV switching dual energy and standard protocols. Effective atomic number of each stone was measured using scanner software. Stone diameter measurements were repeated twice to determine intra-rater variation and compared to actual stone diameter as measured by micro CT.

RESULTS: The chemical composition of three stones (one calcium phosphate and two carbonite apatite) could not be determined using the scanner software. The composition of 10/12 remaining stones was correctly identified using dual energy computed tomography (83% absolute agreement; k = 0.69). No statistical difference (p = 0.051) was noted in the mean stone diameter as measured by clinical CT and micro CT.

CONCLUSION: Dual energy computed tomography using fast kV switching may potentially be developed as a low dose clinical tool for identifying and classifying renal stones in vivo supporting clinical decision-making.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Mussmann B, Hardy M, Jung H, et al. Can Dual Energy CT with Fast kV-Switching Determine Renal Stone Composition Accurately? Acad Radiol. 2020. PMID: 32217056. doi:10.1016/j.acra.2020.02.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。